HP proliant dl580 Manual De Usuario

Descargar
Página de 104
 
Removal and replacement procedures  15 
 
Power down the server (on page 
If you must remove a server from a rack or a non-hot-plug component from a server, power down the 
server. 
 
Remove the server from the rack (on page 
If the rack environment, cabling configuration, or the server location in the rack makes it difficult to 
service the unit, remove the server from the rack. 
 
Remove the access panel ("
" on page 
If you are servicing internal components, remove the access panel. 
 
Remove the system cage ("
). 
If you must remove the system board, power backplane, or the BBWC, remove the system cage. 
 
Extending the server from the rack 
The design of the server enables you to access several components through the front of the server. 
Installing or accessing the following components will not require extending the server from the rack: 
 
Processors 
 
PPMs 
 
Memory boards 
 
DIMMs 
 
Media drive 
 
Diskette drive 
 
Hard drives 
To extend the server from the rack: 
1.
 
Release the two levers on the lower outside corners of the rack. 
  NOTE:  If the server is in a rack and in the shipping configuration, remove the two shipping screws directly 
behind the levers and the two shipping screws on the rails in the rear of the server. 
  IMPORTANT:  If the server is installed in a telco rack, remove the server from the rack to access internal 
components. 
2.
 
Extend the server on the rack rails until the server rail-release latches engage.