Contents 95 
 
 
 
Table 12 
 POST Error Message
 
Error-Code  
Error Message 
Description / Corrective Action 
 
Microcode Error 
BIOS could not find or load the CPU 
Microcode Update to the CPU. The message 
is most likely to appear when a new CPU is 
installed in a system board with outdated 
BIOS. In this situation, you must update the 
BIOS to include the Microcode Update for the 
new CPU. 
 
Checking NVRAM Update Failed 
BIOS could not write to the NVRAM block. 
This message appears when the FLASH part is 
malfunctioning. 
 
Operating system not found 
Operating system can not be located on any 
of the boot drives 
Verify that the priority boot drive has power 
and that the IDE cable is connected properly. 
Verify that the desired boot drive has power. 
Verify that the IDE cable is securely plugged 
into the respective system board connectors. 
Verify that the boot device is enabled in the 
Setup Utility. 
Verify that the boot device has an operating 
system installed. 
If the problem persists, contact your HP 
Customer Support provider. 
60F 
Fan Solution Not Sufficient! 
Critical Failure Detected – System Shutting 
Down in 15 Seconds! 
The non-redundancy fan is not installed, user 
should install the system fan. The system will 
shut down. 
601 
BMC Not Responding 
BMC not responding, you can load the 
optimal default value, or you must change the 
LO100 card. 
603 
System Fan 1 Missing 
System fan 1 is not installed, user should 
install the system fan 1. 
604 
System Fan 2 Missing 
System fan 2 is not installed, user should 
install the system fan 2. 
605 
System Fan 3 Missing 
System fan 3 is not installed, user should 
install the system fan 3. 
606 
System Fan 4 Missing 
System fan 4 is not installed, user should 
install the system fan 4. 
607 
System Fan 5 Missing 
System fan 5 is not installed, user should 
install the system fan 5. 
608 
System Fan 6 Missing 
System fan 6 is not installed, user should 
install the system fan 6. 
610 
Temperature violation Detected 
Wait 5 minutes for system to cool. 
Press ESC key is not recommended as system 
may shutdown unexpectedly.