HP 457626-001 Manual De Usuario

Descargar
Página de 103
 
 
Contents 96 
 
 
 
Table 12 
 POST Error Message
 
Error-Code  
Error Message 
Description / Corrective Action 
611 
System Event Log full 
You must enter BIOS Setup Utility and then 
Clean the System Event Log. 
POST Related Troubleshooting  
Perform the following procedures when POST fails to run, displays error messages. 
If the POST failure is during a routine boot up, check the following: 
 
All external cables and power cables should be firmly plugged in. 
 
The power outlet to the server should be connected and works correctly. 
 
The server and monitor are both turned on. The bicolour status LED indicator on the front panel 
must be lit up green. 
 
The monitor's contrast and brightness settings are correct. 
 
All internal cables are properly connected and all boards firmly seated. 
 
The processor is fully seated in its socket on the system board. 
 
The cooler assembly is properly installed on top of the processor. 
 
All memory modules are properly installed. 
 
If you have installed a PCI accessory board, verify that the board is firmly seated and any 
switches or jumpers on the board are properly set. Refer to the documentation provided with the 
accessory board. 
 
All internal cabling and connections are in their proper order. 
 
If you have changed any switches on the system board, verify that each is properly set.