Ariens sno-thro 921020 Manual De Usuario

Descargar
Página de 44
GB - 25
CHECK CLUTCH OPERATION
Auger / impeller must stop within 5 seconds 
when attachment clutch/impeller brake lever 
is released.
Wheels must stop quickly when traction drive 
clutch lever is released.
If clutches do not engage or disengage 
properly, adjust or repair before operation. 
See Attachment Clutch/Brake Adjustment on 
page 30 and 
Traction Drive Clutch Adjustment on page 32.
CHECK CLUTCH SPRING 
ADJUSTMENT
Make sure the attachment clutch and traction 
drive clutch are adjusted to the range 
specified in Check Clutch Spring Adjustment 
on page 25.
CLEAN ENGINE
Refer to Engine Manual for detailed 
instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked 
every 5 hours of operation. Oil level MUST be 
maintained in safe operating range on 
dipstick at all times or engine damage will 
result (See Engine Manual).
Park unit on a level surface. Refer to Engine 
Manual for detailed instructions.
CHANGE ENGINE OIL
Change oil after first 2 hours of operation, 
thereafter change oil every 25 hours (more 
often if required). Refer to Engine Manual for 
detailed instructions.
Run engine just prior to changing oil. Warm 
oil will flow more freely and carry away more 
contamination. Remove the oil drain plug 
from the rear of the unit and tip the unit back 
to help drain all the oil. 921019, 020-Remove 
right wheel to allow better access to oil drain. 
CHECK TIRE PRESSURE
 (
921011, 012, 013, 017, 018, 019, 
020
)
Keep tires at pressure listed on the tire 
sidewall. See Check Tire Pressure on 
page 12.
CHECK AUGER GEARCASE 
IMPORTANT: 
Proper oil level must be 
maintained.
Gear cases are filled to the correct level at 
the factory. Unless there is evidence of 
leakage, no additional lubricant should be 
required. Check oil level each season or 
every 25 hours of operation.
To ensure adequate lubricant level:
1. Remove filler plug (Figure 25). Lubricant 
must be at least up to bottom of lubricant 
filler hole with unit resting on a level-
surface.
2. Add lubricant if required. Allow oil to 
drain to level of plug and replace plug. 
IMPORTANT: 
Use only Ariens special gear 
lubricant L-2 (Part Number 00008000). 
Gearcase filler plug may require an 
application of Loc-Tite® 565 thread sealant 
with repeated servicing.
Figure 25
1. Auger Gearcase
2. Oil Fill and Drain Plug
2
1
OS7132