SMSC LAN9311 Manual De Usuario

Descargar
Página de 460
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Datasheet
SMSC LAN9311/LAN9311i
375
Revision 1.4 (08-19-08)
DATASHEET
 
14.5.3.6
Switch Engine ALR Command Status Register (SWE_ALR_CMD_STS)
This register indicates the current ALR command status.
Note 14.62
The default value of this bit is 0 immediately following any switch fabric reset and then self-
sets to 1 once the ALR table is initialized.
Register #:
1808h
Size:
32 bits
BITS
DESCRIPTION
TYPE
DEFAULT
31:2
RESERVED
RO
-
1
ALR Init Done
When set, indicates that the ALR table has finished being initialized by the 
reset process. The initialization is performed upon any reset that resets the 
switch fabric. The initialization takes approximately 20uS. During this time, 
any received packet will be dropped. Software should monitor this bit before 
writing any of the ALR tables or registers.
RO
SS
0
Make Pending
When set, indicates that the Make Entry command is taking place. This bit 
is cleared once the Make Entry command has finished.
RO
SC
0b