Air Inlet Liner (for combustion air) When 
terminating the air inlet liner at this point, a 
positive flue connection is required (to ensure 
combustion air is drawn down the chimney 
only).
Exhaust 3" (75mm) UL 
1777. A full length liner 
is required from the 
exhaust outlet on appli-
ance to center collar of 
termination cap.
Positive Flue Con-
nection (sealing 
fireplace throat 
using a noncombus-
tible seal-off plate 
or insulation).
The outside air inlet does not 
require a full reline (if intake 
liner is terminated in chimney 
and a positive flue connection 
is achieved as specified).
Ai
r I
nl
et
Ex
ha
us
t
Ai
r I
nl
et
Existing Fireplace Flue
(chimney)
Masonry and Factory Built Fireplaces
Figure 6a - Terminating Air Inlet in Chimney 
NOTE: Terminating the air intake liner as shown here may not be al-
lowed by some local codes.  Check with the authority having jurisdiction 
for your area.
Note:  The minimum vertical rise (exhaust vent) is 10 feet (3.1 M) and the 
maximum vertical rise is 35 feet (10.7 M). These dimensions are measured 
from the starting collars of the unit to the end of the vent pipe.
The fireplace and fireplace chimney must be clean and in good working 
order and constructed of non-combustible materials. Inspect chimney 
cleanouts for proper fit and seal.
* Other approved vent components include; Standard Simpson Dura-
vent Co-linear Chimney Liner Kit, Direct-Vent Termination #991, Liner 
Termination Kit (includes termination connector and flashing) #923GK 
and 3" x 35' Alum Flex #2280
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Vertical Venting
The vent pipes must be connected to the proper collars on the unit and 
the exhaust vent pipe must be connected to the termination cap or the 
unit will not operate.
The combustion air intake pipe can be connected to the termination cap 
(see Figure 6b) or it can terminate inside the chimney (see Figure 6a).  
If combustion air intake pipe is terminated inside the chimney and not 
connected to the actual termination cap the bottom opening of the chim-
ney (chimney throat) must be sealed around the vent pipes.  Use a non 
combustible seal-off plate (i.e. 22 gage sheet steel) or unfaced fiberglass 
insulation (8 lb per square foot density minimum) to seal around the vent 
pipes.  Whichever “seal off” method is used must effectively seal the area 
to prevent room air passage to the chimney of the fireplace.  The insulation 
may give off an odor during the first hour of operation.
Venting Installation
Your Superior™ gas insert must be vented to the outside in accordance 
with the current edition of the National Fuel Gas Code ANSI-Z223.1 (In 
Canada,  the  current  CAN/CSA    B149.1  installation  code).    The  insert 
must not be connected to a chimney flue serving a separate solid fuel 
burning appliance.
This gas insert requires a 3” diameter listed flex liner. The vent should 
terminate with a listed direct-vent termination cap. The chimney should be 
sealed around the cap to prevent air and rain from entering the chimney. 
Adhere to the vent manufacturer's instructions for installation and vent 
termination. These appliances are approved for use with the following 
vent kits.
Vertical Cap
Termination 
Connector
Exhaust
Intake
Combustion Air Intake
The existing fireplace chimneys 
may  take  various  contours 
which  the  flexible  liners  will 
accommodate. However, keep 
the flexible liner as STRAIGHT 
as possible, avoid unnecessary 
bending.
Liner Requirements:
Vertical Height Min. = 10 ft. (3.1 M)
Vertical height Max. = 35 ft. (10.7 M)
Note: Measured from flue collar on 
unit to the end of the vent pipe or liner
Use 3" (76 mm) diameter listed gas 
vent liner (UL1777 ONLY) for the 
EXHAUST
Use 3" (76 mm) diameter listed 
liner (UL 181 or UL1777) for the 
AIR INTAKE.
The flexible vent pipe 
must NOT be allowed to 
sag behind  insert or in 
fireplace flue.
Make sure that both liners will pass through existing damper area. Remove 
or lock damper to allow the passage of the flexible liners. If the damper 
will not allow the passage of both liners, DO NOT PROCEED FURTHER.  
(If fireplace is masonry) Consult a local mason for removal of the damper 
without risk of structural damage or leakage (if the fireplace is factory 
built) The appliance may NOT be installed into the fireplace.
Figure 6b
        
WARNING
Direct-Vent Fireplace Insert Vent Requirements - Use liner 
listed to UL181 (Factory-made Air Ducts And Air Connec-
tors) or UL1777 (Chimney Liners) for the AIR INTAKE.  Use 
liner listed to UL1777 ONLY for the EXHAUST.
Do not substitute the heat-rated flex liner (UL1777) for the 
exhaust with any other type liner or a fire may result caus-
ing property damage, personal injury or loss of life.
The standard cap in Termination Kit TKDVI, and in 
Vent Kit DV3FK35
 
is a high wind cap
Vent Kits 
Cat. No.
Model
Description
H0909
FKDVI
Flex Liner Kit, DVI 3” X 35’ (requires 2, one for 
exhaust and one for intake)
TKDVI
TKDVI
Termination Kit, DVI (termination cap and flashing)
DV3FK35 DV3FK35 Flex Liner and Termination Kit, 3" X 35' (includes 2 
flex liners, termination and gear clamps)