Superior arched face kits sdvi Manual De Usuario

Descargar
Página de 28
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Insert Dimensions
Minimum Fireplace Opening Required
A  =  31-1/4” (794mm) Front Opening
B  =  17-1/4” (438mm) Height
C  =  19” (483mm) Rear Width**
D  =  16” (406mm) Fireplace Depth
*  Top air duct will need to be removed for short ZC applications. Replace 
tap tights when removed.
**This dimension is with the air duct hood removed (see Zero Clearance 
Fireplace Installation on Page 11).
Minimum Fireplace Cavity
Top View
Side View
Insert Dimensions
Width of insert behind Surround Panels
31-1/4" (794mm)
Rear height
17-1/4" (438mm)
Insert depth into fireplace
15-3/4" (400mm)
Flue center line from back of surround with 45º collar 13-3/4" (349mm)
Flue collar diameter (OD)
2-15/16" (75mm)
Figure 1
Figure 2
Figure 3
31-1/4”(794mm)
7-1/4”
(184mm)
2-1/2”
(64mm)
15-3/4”
(400mm)
Air Intake
Flue
13”
(330mm)
14-1/2”
(368mm)
16”(406mm)
17-1/4”
(438mm)
7-1/2”
(191mm)
15-1/4”
(387mm)
       CAUTIONS 
 
Trim panels or surrounds must not seal ventila-
tion openings in the existing fireplace that the 
appliance is installed in.
 
The fireplace in which this gas insert is to be 
installed must be thoroughly cleaned if it has 
been used to burn wood or synthetic logs. Have 
the chimney and all inside surfaces of the fire-
place brushed and vacuumed so that no soot, 
embers, or loose combustion deposits can be 
drawn into the heat circulation blower and blown 
into the living area. 
 
If any portion of the chimney system shows signs 
of structural or mechanical weaknesses, such 
as:  cracks,  leaky  joints,  corroded  or  warped 
surfaces,  the  faulty  portion  must  be  repaired 
or replaced prior to installing this appliance.
 
The factory built firebox must accept the insert 
without modification other than removing bolted 
or  screwed  together  pieces  such  as  baffles  / 
smoke shelf / deflectors, ash lips, glass door, 
screen or door tracks, log grates, refractory or 
masonry  lining  and  damper  assemblies.  Any 
fireplace component, which is removed, must be 
retained so they can be reinstalled to restore the 
fireplace to its original operating condition. The 
removal of any part must not alter the integrity 
of the outer shell of the pre-engineered fireplace 
cabinet in any way.  Any parts removed must be 
replaceable.  If any components are removed 
from  (or  altered)  from  the  existing  fireplace, 
a Warning Label (see Page 5) must be affixed 
inside the fireplace firebox, so that it shall be 
visible upon removal of the fireplace insert.  Note: 
RTV high temperature silicone is an approved 
adhesive to affix the label. 
A
B
C
D