 Diagnostics and General Troubleshooting
7 - 11
Access to Screens and Systems
The monitor screen 
remains blank when you 
pick up the remote control.
The monitor’s power cord is 
not plugged in.
Connect the monitor’s power cord and then power on 
the monitor.
The monitor is powered off.
Power on the monitor.
The monitor is not 
connected correctly to the 
system.
Verify that the monitor is connected correctly 
according to the manufacturer’s instructions and the 
setup sheet you received with the system.
The monitor is not set to 
use the signal input that is 
connected to the VSX 
system.
On the monitor, change the signal input. 
The image may take a few seconds to synchronize 
after you select the signal input that is connected to 
the VSX system.
The remote control does 
not work in voice-only calls 
using the 
SoundStation VTX 1000 
conference phone.
This is normal.
Use the SoundStation VTX 1000 conference phone 
controls in voice-only calls.
The system does not 
respond to the touch-panel 
control.
The RS-232 serial port is 
not configured as a 
touch-panel input.
Go to Admin Settings > General Settings > Serial 
Port
 and verify the following:
Baud  Rate is set to the same value on the 
system as on the touch-panel.
RS-232 Mode is set to Control.
VSX 7000e, VSX 8000: The touch-panel is 
connected to the port that is configured as a 
touch-panel port.
Symptom
Problem
Corrective action
Cannot navigate to Admin 
screens — System button 
is not displayed.
The home screen is not 
configured to display the 
System button.
Press the 
 button on the remote and select 
System at the end of the help message, or access 
the system remotely using VSX Web, FTP, Telnet, or 
SNMP.
From VSX Web, you can add the System button 
back to the home screen. Click System Setup and 
navigate to Admin Settings > General Settings > 
Home Screen Settings
, then select System. The 
change takes effect after you navigate away from the 
home screen and then back again on the system.
Cannot navigate to Admin 
screens without a 
password.
The system administrator 
has set a password,
or
The default password was 
not deleted.
Enter the password.
The default password is the system’s serial number.
Symptom
Problem
Corrective action