Chapter 3 - Configuring Network Use
© Polycom, Inc.
3-19
To configure serial interface control signals:
The system can provide standard or inverted signal polarity. Refer to the documentation 
supplied with the device you have connected to the V.35/RS-449/RS-530 network interface 
module to determine whether you need to change signal polarity. Do not change signal 
polarity unless your equipment requires it. Incorrect signal polarity settings will prevent the 
equipment from working properly. 
1.
Go to System Info> Admin Settings > Video Network > Advanced V.35.
2.
Configure these settings:
To choose a calling profile for the connected equipment:
1.
Go to System Info > Admin Setup > Video Network and enable RS-366 
Dialing
.
2.
Select Advanced Dialing and configure these settings:
Setting
Description
ST
Lets you specify the signaling required by the external 
device connected to the system. Specify normal or 
inverted, as appropriate. In most cases, normal signaling 
is appropriate.
RT
RTS
DCD
CTS
DTR
DSR
Setting
Description
Prefix
Lets you specify the dialing prefix required to reach an outside 
line.
Calling Profile
Lets you specify what data communications equipment is 
connected to the network interface. The system automatically 
displays the default prefixes, suffixes, and calling speeds required 
by that device.
If your device is not listed, choose Custom.
Speed 
Lets you define the prefixes or suffixes to use for each speed used 
in a Custom Calling Profile. For information about required 
prefixes and suffixes, see the documentation that came with the 
device.
If you choose a predefined Calling Profile, this information is 
supplied for you.