Disassembly Procedures
Reinstalling Lid Switch
1. Insert the lid switch assembly in the Top Cover (Push
the switch assembly straight down and back until it
locks in place).
Unbalance Lever and Plunger Assembly
1. Disconnect  power supply to unit.
2. Remove Lid and tilt  the Top cover backwards.
3. Remove two screws securing the plunger assembly to
the Top Cover.
Front Of
Machine
Front Of
Machine
Top
Cover
Top
Cover
RIGHT!
WRONG!
Unbalance
Lever
Plunger Assembly
Pressure Switch
1. Disconnect power supply to unit.
2. Remove Control Panel.
3. Disconnect wires attached to the switch.
4. Remove clamp securing Air Dome Hose.
5. Remove two screws securing Pressure Switch to the
Top  Cover.
Air Dome
1.  Disconnect power supply to unit.
2.  Remove Control Panel and  rear access service plate.
3.  Remove clamp securing rubber hose to the Pressure
Switch.
4.  Remove clamp securing Air Dome to the Outer Tub
spout.
5.  Disconnect  rubber air tube secured to the cabinet.
6.  Remove the air dome hose through the rear access
opening.