Maytag w10222378a Manual De Usuario

Descargar
Página de 32
14
Secure the Drain Hose
1. Move the washer/dryer to its final location and remove any 
cardboard used to move the washer/dryer.
2. Locate the remaining piece of shipping strap. See “Remove 
Shipping Strap.”
Shipping strap
3. Wrap the drain hose to the laundry tub leg or standpipe with 
the shipping strap (A or B below). Push fastener into the 
nearest hole in the shipping strap (see illustration above). 
If the water faucets and the drain standpipe are recessed, put 
the hooked end of the drain hose in the standpipe. Tightly 
wrap the shipping strap around the water inlet hoses and the 
drain hose (C above). Push fastener into the nearest hole in 
the shipping strap (see illustration above).
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the washer/
dryer. Other installations are possible.
Optional exhaust installations 
This washer/dryer can be converted to exhaust out the right 
or left side. To convert the washer/dryer, use Side Exhaust Kit 
Part Number 279823. If your washer/dryer was previously 
exhausted from the right or left side, it can be converted to rear 
exhaust by using standard offset connections. To cover the hole 
in the side, one of the following plugs can be added:
692790 (white)
3977784 (biscuit)
Follow the instructions in the kit to install. Kits are available from 
the dealer from whom you purchased your washer/dryer. 
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for 
your installation. Three close-clearance installations are shown. 
Refer to the manufacturer’s instructions provided with the vent 
system.
NOTE: The following kits for close clearance alternate installations 
are available for purchase. Please reference the “Assistance or 
Service” section of the Washer/Dryer User Instructions.
Over-the-Top Installation: 
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent 
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm) 
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) 
mismatch
A. Dryer
B. Rigid metal or flexible metal vent
C. Clamps
D. Wall
E. Elbow
F. Clamps
G. Elbow
H. Exhaust hood
B
C
A
A
B
C
D
E
F
G
H
A. Standard rear offset exhaust installation
B. Rear exhaust for offset close clearance connection
C. Left or right side exhaust installation
 A. Loop system with standard elbows
B. Loop system with one offset and one standard elbow
C. Vent system with one periscope (2" [51 mm] clearance)
A
B
C
A
B
C