141 
network includes LMF-200 or LMF-400 digital gauges, which support 
the display of fewer electronic probes than your GPS or sonar/GPS unit. 
If you want to use your unit in a network including one of these digital 
gauges, you may need to consult customer service. You should never 
need this command if you are connecting your unit to a network with 
similar display units and/or a series of electronic probes.  
Restore Defaults 
The Restore Defaults command allows you to reset an individual en-
gine interface's settings to factory defaults. If, for example, you execute 
the Restore Defaults command from your Port Engine Interface Ad-
vanced Options menu, only the settings for the Port Engine Interface 
will be reset to factory defaults. Other engine interfaces on the network 
will not be affected. 
To restore default settings: 
1. Press 
MENU| MENU
, use 
↑ ↓  to select 
NMEA
 
2000
 and press 
ENT
. The 
NMEA 2000 menu will appear with five options: Bus Setup, Fuel Man-
agement, NMEA 2000 Alarms, Waypoint Sharing and Backlight Syn-
chronization.  
2. Highlight 
B
US 
S
ETUP
 and press 
ENT
.  
3. Use 
↑ ↓ to select the desired fluid level and press 
ENT
. The Device 
Configuration menu will appear.  
4. Highlight 
A
DVANCED 
O
PTIONS
 and press 
ENT
.  
5. Select 
R
ESTORE 
D
EFAULTS
 and press 
ENT
. The following message will 
appear: Are you sure you wish to change this device's configuration?  
6. Highlight 
Y
ES
 and press 
ENT
. Press 
EXIT
 repeatedly to get back to the 
main display. 
NOTE: 
The Suzuki Engine Interface Device Configuration menu contains 
two Engine Trim calibration commands, which will be addressed in 
the next segment of this section, Calibrating EP Sensors.    
Calibrating EP Sensors 
The factory calibration settings for the EP-10 Fuel Flow, EP-15 Fluid 
Level and Suzuki Engine Interface should be adequate for the majority 
of applications, so calibration will not be necessary in most cases.  
EP-10 Fuel Flow Calibration 
The default calibration for the EP-10 Fuel Flow is adequate in most 
cases, but if Fuel Used readings are off by more than 3 percent, calibra-
tion is recommended. 