IBM totalstorage ds4500 Manual De Usuario

Descargar
Página de 16
swapping
 
these
 
mini-hubs,
 
you
 
will
 
not
 
need
 
to
 
schedule
 
down
 
time
 
later
 
for
 
re-cabling
 
the
 
drive
 
loop
 
if
 
additional
 
mini
 
hubs
 
are
 
installed
 
to
 
enable
 
a
 
second
 
redundant
 
drive
 
loop.
 
 
Attention:
  
Re-cabling
 
of
 
drive
 
loops
 
to
 
different
 
drive
 
mini
 
hubs
 
in
 
an
 
operating
 
DS4500
 
Storage
 
Subsystem
 
configuration
 
requires
 
down
 
time
 
for
 
the
 
configuration.
 
 
If
 
you
 
have
 
an
 
existing
 
DS4500
 
Storage
 
Subsystem
 
configuration
 
with
 
mini
 
hubs
 
in
 
slots
 
1
 
and
 
2
 
and
 
you
 
plan
 
to
 
add
 
an
 
additional
 
redundant
 
drive
 
loop,
 
you
 
must
 
re-cable
 
your
 
existing
 
configuration
 
as
 
shown
 
in
 
 
If
 
you
 
can
 
schedule
 
down
 
time
 
before
 
you
 
are
 
ready
 
to
 
add
 
the
 
new
 
drive
 
loop
 
in
 
the
 
system
 
(or
 
whenever
 
it
 
is
 
possible
 
to
 
make
 
the
 
changes
 
to
 
the
 
mini
 
hubs
 
and
 
the
 
drive
 
side
 
FC
 
cabling),
 
you
 
will
 
not
 
have
 
to
 
schedule
 
down
 
time
 
when
 
you
 
are
 
ready
 
to
 
add
 
the
 
new
 
drive
 
loop
 
in
 
the
 
system.
 
Note:
  
If
 
you
 
have
 
an
 
existing
 
DS4500
 
Storage
 
Subsystem
 
configuration
 
with
 
mini
 
hubs
 
in
 
slots
 
1
 
and
 
2,
 
and
 
you
 
do
 
not
 
plan
 
to
 
add
 
an
 
additional
 
redundant
 
drive
 
loop,
 
do
 
not
 
make
 
any
 
changes
 
to
 
the
 
positions
 
of
 
your
 
mini
 
hubs.
 
shows
 
a
 
storage
 
subsystem
 
containing
 
one
 
DS4500
 
Storage
 
Subsystem
 
populated
 
with
 
two
 
mini
 
hubs
 
and
 
one
 
redundant
 
drive
 
loop
 
with
 
two
 
storage
 
expansion
 
enclosures,
 
as
 
the
 
DS4500
 
was
 
shipped
 
previously,
 
with
 
mini
 
hubs
 
installed
 
in
 
mini
 
hub
 
slots
 
1
 
and
 
2.
 
“Storage
 
Expansion
 
Enclosure
 
Group
 
1”
 
uses
 
a
 
redundant
 
drive
 
loop
 
to
 
connect
 
to
 
the
 
DS4500
 
Storage
 
Subsystem.
 
Loop
 
A
 
and
 
loop
 
B
 
make
 
up
 
one
 
redundant
 
pair
 
of
 
drive
 
loops.
 
 
Drive Loop A
Drive Loop B
Drive Loop A Fibre
Channel interface
Cables
Drive Loop B Fibre
Channel interface
Cables
First DS4000 drive
enclosure
Last DS4000 drive
enclosure
Storage Expansion
Enclosures -
Group 1
DS4500 Storage
Subsystem
Input
Input
Output
Output
Drive minihub 4
Drive minihub 2
ds452minb
  
Figure
 
7.
 
Redundant
 
drive
 
loop
 
cabling
 
overview
 
with
 
two
 
mini
 
hubs
 
in
 
slots
 
4
 
and
 
2
 
9