Bunn H5X Manual De Usuario

Descargar
Página de 25
19
SERVICE (cont.)
Solenoid Valve
Location:
The  solenoid  valve  is  located  inside  the  rear  of  the 
dispenser on the right side near the bottom.
To test the solenoid valve, access will also be needed 
to the electronic control board.
7.  Check the solenoid valve for coil action. Connect 
the dispenser to the power source. Listen carefully 
in the vicinity of the solenoid valve for a “clicking” 
sound after approximately 5 seconds, as the coil 
magnet attracts the plunger.
8.  Disconnect the dispenser from the power source.
9.  Reconnect the pink wire to terminal 5 of the elec-
tronic control board.
If the sound was heard as described and water will 
not pass through the solenoid valve, there may be a 
blockage in the water line before or after the solenoid 
valve or the solenoid valve may require inspection for 
wear and removal of waterborne particles.
If the sound was not heard as described, replace the 
solenoid valve.
Removal and Replacement:
1.  Remove all wires from the solenoid valve coil.
2.  Turn-off the water supply to the dispenser.
3.  Disconnect  the  water  line  from  the  solenoid 
valve.
4.  Remove the two 8-32 slotted-head screws holding 
the solenoid valve and mounting bracket to the back 
panel.
5.  Lift-out the solenoid valve.
6.  Securely install the new solenoid valve to the back 
panel.
7.  Securely  fasten  the  water  line  to  the  solenoid 
valve.
8.  Reconnect the wires, FIG. 8.
WARNING
!
Test Procedure:
1.  Disconnect the dispenser from the power source 
and turn-off the water supply to the dispenser.
2.  Remove the pink wire from terminal 5 of the elec-
tronic control board.
3.  Check  the  voltage  across  the  solenoid  valve  coil 
terminals with a voltmeter. Connect the dispenser 
to the power source. The indication must be:
 
a.) 100 to 120 volts ac for 100 to 120 volt models 
or
 
b.) 200 to 240 volts ac for 200 to 240 volt models
 
or
 
c.) 230 volts ac for 230 volt models 
 
after a delay of approximately 5 seconds.
4.  Disconnect the dispenser from the power source.
If voltage was present as described, proceed to #5.
If voltage was not present as described, refer to the 
Wiring Diagrams and check the dispenser wiring har-
ness.
5.  Remove  both  wires  from  the  solenoid  valve  coil 
terminals.
6.  Check for continuity across the solenoid valve coil 
terminals.
If continuity is present as described, reconnect the wires 
and proceed to #7.
If continuity is not present as described, replace the 
solenoid valve coil.
FIG. 7 SOLENOID VALVE
FIG. 8 SOLENOID VALVE WIRING
WHI/BLU to Electronic 
Control Board T1
P1778
10420.1 040309
WHI or RED to 
Terminal Block