SERVICE (cont.)
Tank Heater
Location:
The tank heater is located in the tank lid.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across the terminals of the tank 
heater with a voltmeter. Connect the dispenser to 
the power source. The indication must be:
 
a.) 100 to 120 volts ac for 100 to 120 volt models 
or
 
b.) 200 to 240 volts ac for 200 to 240 volt models
 
or
 
c.) 230 volts ac for 230 volt models.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, replace the tank 
heater.
4.  Remove the tank heater from the tank lid and inspect 
it for cracks in the sheath.
If  the  sheath  shows  no  sign  of  damage,  proceed  to 
#5.
If the sheath is damaged, replace the tank heater.
5.  Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reinstall the tank 
heater. The tank heater is operating properly.
If continuity is not present as described, replace the 
tank heater.
FIG. 9 TANK HEATER
FIG. 10 TANK HEATER WIRING
This 
equ
ipment 
is to be ins
talled to
comp
ly with the Basic Plumbing C
ode o
f
the Building Of
ficials
 and Code
Administ
rato
rs Internationa
l, Inc.
 (BOCA)
and
 the Food Ser
vice Sanitation Ma
nual
of the Food and Drug 
Administ
ratio
n (FDA
).
BLK to Limit 
Thermostat
BLU to Control 
Board Relay
P1780
P4093
Removal and Replacement:
1.  Remove the wires to the tank heater.
2.  Remove  the  8-32  nuts  from  the  tank  heater 
flange.
3.  Remove the tank heater.
4.  Inspect the tank heater gasket and replace if neces-
sary.
5.  Securely install the new tank heater. Be certain of 
a watertight seal.
6.  Reconnect the wires, FIG. 10.
10420.1 040309