Menu Maps
3-4
April 2004
*Use 200 kHz
Table 3-1:  PT878GC Installation Requirements
Pipe Size
in. (mm)
Transducer 
Frequency 
(MHz)
Installation Requirements for Minimum Required Pressure with Resultant Maximum Flow
Number of 
Traverses
Pipe Wall 
Thickness in. 
(mm)
Pressure  psig (bar)
Maximum Flow Velocity  ft/s (m/s)
Air
NG
Air
NG
Steam
4” (100)
0.5
1
<0.24 (6.1)
60 (5.1)
150 (11.4)
120 (36.6)
120 (36.6)
120 (36.6)
1
<0.34 (8.6)
180 (13.4)
400 (28.6)
3*
<0.68 (17.3)
300 (21.7)
800 (56.2)
6” (150)
0.5
1
<0.28 (7.2)
60 (5.1)
150 (11.4)
90 (27.4)
120 (36.6)
120 (36.6)
1
<0.44 (11.2)
180 (13.4)
400 (28.6)
3*
<0.87 (22.1)
300 (21.7)
800 (56.2)
8” (200)
0.5
1
<0.33 (8.4)
60 (5.1)
175 (13.1)
80 (24.4)
100 (30.5)
100 (30.5)
1
<0.5 (12.7)
180 (13.4)
400 (28.6)
3*
<0.88 (22.4)
300 (21.7)
800 (56.2)
10” (250)
0.5
1
<0.37 (9.4)
60 (5.1)
200 (14.8)
70 (21.3)
85 (25.9)
85 (25.9)
1
<0.5 (12.7)
180 (13.4)
500 (35.5)
3*
<1.0 (25.4)
300 (21.7)
800 (69)
12” (300)
0.5
1
<0.38 (9.7)
60 (5.1)
250 (18.3)
55 (16.8)
70 (21.3)
70 (21.3)
1
<0.5 (12.7)
180 (13.4)
500 (35.5)
1
<1.0 (25.4)
300 (21.7)
800 (56.2)
14” (350)
0.2
1
<0.38 (9.7)
90 (7.2)
300 (21.7)
50 (15.2)
60 (18.3)
N/A
1
<0.5 (12.7)
270 (19.6)
800 (56.2)
16” (400)
0.2
1
<0.38 (9.7)
90 (7.2)
300 (21.7)
40 (12.2)
54 (16.5)
N/A
1
<0.5 (12.7)
270 (19.6)
800 (56.2)
18” (450)
0.2
1
<0.38 (9.7)
90 (7.2)
300 (21.7)
35 (10.7)
50 (15.3)
N/A
1
<0.5 (12.7)
270 (19.6)
800 (56.2)
20” (500)
0.2
1
<0.38 (9.7)
90 (7.2)
300 (21.7)
35 (10.7)
43 (13.1)
N/A
1
<0.5 (12.7)
270 (19.6)
800 (56.2)
24” (600)
0.2
1
<0.38 (9.7)
90 (7.2)
300 (21.7)
30 (9.1)
36 (11)
N/A
1
<0.5 (12.7)
270 (19.6)
800 (56.2)