GTO pro-sl 51006100 Manual De Usuario

Descargar
Página de 31
16
Diagnostic LEDs 
(Press LEARN / RESET to clear these LEDs)
PWR OK: Power (115 Vac) is being delivered to the unit.  This
light will not be on when operator is in “LEARN” mode and will
PLUSE when system in running on battery backup.
TIMER ON: The auto-close timer has been enabled.
OBSTRUCT: An obstruction has been encountered.
MAX TIME: Indicates operator ran longer than 110 seconds
without reaching a limit switch and the motor has shut OFF.
Error Condition LEDs 
(Press LEARN / RESET to clear these LEDs)
SENSOR ERR.: Indicates obstruction sensing circuitry has
malfunctioned.
LIM SW ERR.: Indicates a fault in the limit switch or limit switch
wiring (this error cannot be reset by pressing the LEARN/RESET button).
OPEN MTR.: Control board does not detect the operator motor.
INTERN ERR.: Indicates a microprocessor error has occurred.  An internal error
cannot be reset by pressing the LEARN/RESET button. The ON/OFF switch
must be turned OFF, then back ON to reset the LED.
PWR OK
TIMER ON
OBSTRUCT
MAX TIME
SENSOR ERR.
LIM SW ERR.
OPEN MTR.
INTERN.ERR.
MIN
MAX
INERTIA
LEARN/RESET
MIN
MAX
CLS. SENS.
EDGE 6
EDGE 5
EDGE 4
EDGE 3
EDGE 2
EDGE 1
COM
COM
DUAL GATE
INTERFACE
RX
TX
GRN
RED
BLK
GTO
RCVR.
+
+
CYCLE
FREE
EXIT
CLOSE
OPEN
FIRE
DEPT.
SHAD.
LOOP
SAFE
LOOP
ENTRY
LOOP
COM
COM
COM
COM
Terminals 
(Note: use common connections for ground.  To ground CLOSE/
OPEN, FIRE DEPT., SHAD. LOOP, ENTRY ENAB, ENTRY LOOP, FREE
EXIT, and CYCLE, use the center post).
DUAL GATE INTERFACE  RX  TX: This terminal allows the addition of a
second gate operator for dual gate systems.  ONLY Belden Wire
®
 (see Installing
a Dual Slide Gate System on pages 22-23) is compatible with this terminal.  All
four (4) connectors plus one (1) COMMON must be wired.
GTO RCVR.: For connecting a GTO receiver ONLY.  Other receivers may be
connected to the 24VDC terminal block (see CAUTION at 24VDC on page 17).
EDGE 1 – EDGE 6 : These six terminals accommodate safety edges and photo
beams.
COM (common): Terminal for connecting a ground wire.
CLOSE/OPEN: OPEN requires constant pressure on entry device to open the
gate; CLOSE requires constant pressure on entry device to close the gate. NOTE:
When a constant pressure entry device is installed the unit will not accept any other
open or close input except FIRE DEPT.
FIRE DEPT.: N/O contact reserved for public safety agency use
(e.g., fire box) only.
SHAD. LOOP: Shadow loop setting for swing gates.
SAFE LOOP: N/O contact that prevents the gate from closing if the safety device
(ground loop, photo beam, etc.) is activated.
ENTRY LOOP: N/O contact for entry device.
FREE EXIT: N/O contact for an exit loop or exit wand.
CYCLE: N/O contact for doorbell button or key switch.
continued on facing page...