Pre-Construction 
Mount 
Kit
 
NOTE:  Use the inside edge of PMK-17L for cutting drywall 
The plate is designed to provide the necessary support for a single touchpanel and 
must mount to the right and left studs. Confirm that the PMK-17L is level before 
application of drywall. A rectangular opening with the dimensions shown in the 
illustration after this paragraph must be made in the drywall. Verify that the opening 
exposes the eight #6-32 tapped holes. 
Dimensions for Drywall Cutout 
 ~13
5
16
 in
(338 mm Max)
DO NOT
EXCEED THIS
DIMENSION
 ~1
5
64
 in
(29 mm Max)
TYP (4X)
 ~5
1
32
 in
(127 mm Max)
 ~6
3
16
 in
(157 mm Max)
 ~16
1
4
 in
(412 mm Max)
 Ø
3
16
 in
(5 mm Max)
TYP (4X)
 ~
5
32
 in
(44 mm Max)
 ~
3
64
 in
(11 mm Max)
 13 in
(330 mm Max)
 ~13
13
94
 in
(335 mm Max)
 
If the opening for the touchpanel in the drywall is too large, two pre-construction 
accessories are available to make adjustments. Use the optional TMK-17L (Trim 
Ring Kit) to provide a smooth edge at the opening. This option provides a finished 
appearance and is preferred when wallpaper is hung. Use the optional MMK-17L 
(Mud Ring Kit) to fill in larger irregularities around the opening (requires 
plastering).  
Complete the installation by either installing the touchpanel, leaving the hole open (if 
permitted by local building codes), or installing the supplied cover plate with the 
included #6-32 x 1½” screws (shown after this paragraph). If the touchpanel is to be 
installed, refer to the latest revision of the TPS-12L/15L/17L Operations Guide (Doc. 
6355) or the  TPMC-15/17-L Series Operations Guide (Doc. 6354) for installation 
instructions. 
Installation Guide - DOC. 6368 
Pre-Construction Mount Kit: PMK-17L  