Crestron pmk-17l Manual De Usuario
Crestron PMK-17L
Pre-Construction
Mount
Kit
NOTE: Use the inside edge of PMK-17L for cutting drywall
The plate is designed to provide the necessary support for a single touchpanel and
must mount to the right and left studs. Confirm that the PMK-17L is level before
application of drywall. A rectangular opening with the dimensions shown in the
illustration after this paragraph must be made in the drywall. Verify that the opening
exposes the eight #6-32 tapped holes.
must mount to the right and left studs. Confirm that the PMK-17L is level before
application of drywall. A rectangular opening with the dimensions shown in the
illustration after this paragraph must be made in the drywall. Verify that the opening
exposes the eight #6-32 tapped holes.
Dimensions for Drywall Cutout
~13
5
16
in
(338 mm Max)
DO NOT
EXCEED THIS
DIMENSION
~1
5
64
in
(29 mm Max)
TYP (4X)
~5
1
32
in
(127 mm Max)
~6
3
16
in
(157 mm Max)
~16
1
4
in
(412 mm Max)
Ø
3
16
in
(5 mm Max)
TYP (4X)
~
5
32
in
(44 mm Max)
~
3
64
in
(11 mm Max)
13 in
(330 mm Max)
~13
13
94
in
(335 mm Max)
If the opening for the touchpanel in the drywall is too large, two pre-construction
accessories are available to make adjustments. Use the optional TMK-17L (Trim
Ring Kit) to provide a smooth edge at the opening. This option provides a finished
appearance and is preferred when wallpaper is hung. Use the optional MMK-17L
(Mud Ring Kit) to fill in larger irregularities around the opening (requires
plastering).
accessories are available to make adjustments. Use the optional TMK-17L (Trim
Ring Kit) to provide a smooth edge at the opening. This option provides a finished
appearance and is preferred when wallpaper is hung. Use the optional MMK-17L
(Mud Ring Kit) to fill in larger irregularities around the opening (requires
plastering).
Complete the installation by either installing the touchpanel, leaving the hole open (if
permitted by local building codes), or installing the supplied cover plate with the
included #6-32 x 1½” screws (shown after this paragraph). If the touchpanel is to be
installed, refer to the latest revision of the TPS-12L/15L/17L Operations Guide (Doc.
6355) or the TPMC-15/17-L Series Operations Guide (Doc. 6354) for installation
instructions.
permitted by local building codes), or installing the supplied cover plate with the
included #6-32 x 1½” screws (shown after this paragraph). If the touchpanel is to be
installed, refer to the latest revision of the TPS-12L/15L/17L Operations Guide (Doc.
6355) or the TPMC-15/17-L Series Operations Guide (Doc. 6354) for installation
instructions.
Installation Guide - DOC. 6368
Pre-Construction Mount Kit: PMK-17L
• 3