f) High Voltage (7-beep alarm)
The maximum allowable supply voltage for this icemaker is limited by the high voltage 
cut-out. When high voltage (147.5Vac ±5% or more) is present, the "POWER OK" LED 
turns off and the control board shuts down the unit and sounds a 7-beep alarm every 
5 seconds. When the proper supply voltage resumes, the unit automatically starts 
running again.
g) Gear Motor (8-beep alarm)
Gear motor operation is confirmed through the gear motor protect relay (control board 
K1 connector). If the white/orange (W/O) wires on the control board K9 connector (gear 
motor protect circuit) do not have continuity (gear motor protect relay de-energized), 
the compressor relay does not energize. If the icemaker is running, and the gear motor 
protect relay de-energizes, the control board shuts down the compressor and gear 
motor and sounds an 8-beep alarm every 5 seconds. This alarm requires a manual 
reset. Turn the power off and then on again to reset the alarm. The icemaker starts 
running. The compressor starts running again when the gear motor protect relay 
energizes. For further details, see "IV.B. Diagnostic Procedure."
h) Bin Control  (9-beep alarm) 
This alarm provides protection to prevent the icemaker from overfilling the ice storage 
bin. If the infrared sensor is signifying the ice storage bin is empty (yellow LED off), and 
the mechanical bin control is signifying the ice storage bin is full (proximity switch open), 
the control board shuts down the unit and sounds a 9-beep alarm every 5 seconds. This 
alarm requires a manual reset. Turn the power off and then on again to reset the alarm. 
For further details, see "IV.D. Bin Control Check."
4. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely 
affect performance and warranty coverage. For more information, contact 
Hoshizaki Technical Support at 1-800-33-1940.
a) Default Dip Switch Settings
The S1 dip switch settings are factory-set to the following positions:
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
FD-1001M_H(-C) ON OFF OFF OFF OFF OFF ON
ON OFF OFF
Infrared Sensor Shutdown Delay
Continuous Dispensing Timer 
(DCM models only, do not adjust on modular icemakers)
Drain Frequency Control
Bin Control Selector 
Mechanical Bin Control Shutdown Delay 
Normally off (factory use)