fetco cbs-2051e Manual De Usuario
11
Temperature Settings
Parameter Name
Range
Default
Setting Comment
7
Water Temp. (
°F) 180°F - 208°F 200°F
Inside tank. Will be slightly lower at
spray head. To display in
spray head. To display in
° Celsius,
see # 58 in Advanced Settings.
8
Hot Water Service
A (auto) / On / Off
A (auto)
A= Faucet will dispense only when not
brewing.
On=Faucet always enabled.
Off=Faucet always disabled.
brewing.
On=Faucet always enabled.
Off=Faucet always disabled.
9
Brew at Set
Temperature
Temperature
0 - 1
1
0=Will brew at any temperature
above 180°F.
1=Will brew only at set temperature.
Note: Changes will not take effect
until one full brew cycle is
completed after the change is
made.
until one full brew cycle is
completed after the change is
made.
Parameter Name
Range
Default
Setting
Comment
10 Enter
Advanced
Settings &
Diagnostics
Diagnostics
0 - 1
0
0 = Skip Advanced Settings &
Diagnostics. Loop back to start of
batch programming cycle.
1 = Enter Advanced Settings &
Diagnostics.
Press STOP to continue
Diagnostics. Loop back to start of
batch programming cycle.
1 = Enter Advanced Settings &
Diagnostics.
Press STOP to continue
Important! To save your changes, press to exit programming mode and return to operating mode.
Advanced Settings and Diagnostics
Address Description
Range
Default
Comment
50 Water
Level
in Tank
0 - 1
Tests if water is touching probe.
0 = Tank is less than full
1 = Tank is full
0 = Tank is less than full
1 = Tank is full
52 Brew
Basket
Sensor State
(left / right)
(left / right)
0 - 1
To test, slide the brew basket in and out. Display
should toggle between 0 and 1.
0 = Brew basket out. 1 = Brew Basket in.
should toggle between 0 and 1.
0 = Brew basket out. 1 = Brew Basket in.
55 Tank
Temperature
180
°F - 208°F
Displays current tank temperature.
56 Brewer
Model
Number
31 - 52
Must be set for the correct model number of the
brewer: 51 for CBS-2051e,
brewer: 51 for CBS-2051e,
52 for CBS-2052e and CBS-2052e20.
57
Reload Defaults
0 - 1
0
Changes all settings to default factory settings.
0 = Do not reload defaults
1 = Reload all default settings
If 1 is selected, you must advance to the next
address for this change to take effect.
Does not change address 56 – model number.
0 = Do not reload defaults
1 = Reload all default settings
If 1 is selected, you must advance to the next
address for this change to take effect.
Does not change address 56 – model number.
58
Temperature Scale F or C
F
F = Displays temp in degrees Fahrenheit
C = Displays temp in degrees Celsius
C = Displays temp in degrees Celsius
59 Water
Volume
Scale
GAL or LTR
GAL
GAL = Displays volume in gallons
LTR = Displays volume in liters
LTR = Displays volume in liters