fetco cbs-2051e Manual De Usuario

Descargar
Página de 24
 
 
13
Error Codes 
Code 
Description 
Possible Cause 
Corrective Action 
How to Clear Error 
Codes 
001 Internal 
Error 
System had to reload 
default settings. 
Control board failure. 
Clear error. 
Re-program the brewer to 
the desired specifications. If 
error occurs again, replace 
control board. 
Turn main power 
switch off and on. 
050 
Shorted temperature probe.  Probe failure. 
Replace probe. 
Turn main power 
switch off and on. 
051 
Open temperature probe. 
Bad probe connection, 
or probe failure. 
Check all connections. 
Replace probe if necessary. 
Turn main power 
switch off and on. 
Brew basket sensor or 
lock has failed. 
Repair or replace brew 
basket sensor or lock. 
Press the flashing 
control panel power 
switch to resume 
operation. 
075 
Brew basket lock or sensor 
failure. 
Basket was in place when 
brew cycle started, but was 
pulled out during the brew 
cycle. If this error occurs, 
the brew basket lock has 
failed. 
Magnet in brew basket 
handle is missing or 
loose. 
Remove brew basket 
handle. Place magnet in 
correct position. 
 
100 
Initial Fill Error 
Initial fill time was more 
than 15 minutes. 
Water supply flow rate 
is too low. 
Watch for short potting 
during brew cycle. 
Investigate cause of low flow 
rate. (Clogged water filter, 
etc.) 
Press the control 
panel power switch.
101 
Error on refill 
Tank did not refill within 3 
minutes. 
Water supply flow rate 
is too low. 
Watch for short potting 
during brew cycle. 
Investigate cause of low flow 
rate. (Clogged water filter, 
etc.) 
Error message is 
cleared 
automatically at 
end of brew cycle. 
Possible leak in tank, 
fitting, or valve. 
Check inside of machine for 
leaks. 
102 Unwanted 
Fill 
When brewer is idle, the fill 
valve was activated for 
more than 30 seconds 
during a 1 hour period. 
Output on control 
board has failed, 
causing a dispense 
valve to open. 
Replace control board. 
Turn main power 
switch off and on. 
200 
Flat Line Temperature 
(Water is boiling) 
System is calling for heat, 
but the temperature does 
not rise at least 2
°F  within 
10 minutes. 
Triac is stuck closed, 
bad output on control 
board, or temperature 
is set too high for 
altitude. 
Check triacs, check control 
board output, or adjust 
temperature for altitude. 
Turn main power 
switch off and on. 
201 Heater 
Open 
System is calling for heat, 
but the temperature does 
not rise at least 2
°F  within 
10 minutes. This error is 
disabled during brewing 
and while using the hot 
water faucet. 
Heating element 
failure. 
Check and replace heating 
elements if necessary. 
Turn main power 
switch off and on. 
202 Heater 
Short 
System is not calling for 
heat, but temperature rises 
more than 5
°F. 
Possible triac stuck 
closed, or bad output 
on control board. 
Check triac and control 
board. 
Enter programming 
mode, then exit 
programming 
mode. 
255 Keypad 
Error 
A switch was pressed for 
more than 45 seconds. 
Switch was held in too 
long, or switch is stuck 
closed. 
Clear error and try again. If 
error occurs without switch 
being pressed, replace input 
board. 
Turn main power 
switch off and on.