INSTALLATION, OPERATION AND CARE OF 
GAS COUNTERTOP HOTPLATE RANGE 
 
GENERAL 
 
Gas Countertop Hotplates are designed for commercial use only and feature fast, efficient 
gas heat.  Each burner is controlled by an adjustable gas valve. Cast grates and burners 
are easily removed for cleaning when cool. 
 
Model 
# of 
Burners 
BTU/hr Input Rating 
Standard & Step-Up 
BTU/hr Input Rating 
Half Hot-Top 
AHP212 / VHP212 
60,000 
45,000 (30,000 + 15,000) 
AHP424 / VHP424 
120,000 
90,000 (60,000 + 30,000) 
AHP636 / VHP636 
180,000 
135,000 (90,000 + 45,000) 
AHP848 / VHP848 
240,000 
180,000 (120,000 + 60,000) 
 
 
INSTALLATION 
UNPACKING 
 
Immediately after unpacking, check for possible shipping damage.  If the hotplate is found 
to be damaged, save the packaging material and contact the carrier within 15 days of 
delivery. 
 
Before installing, verify that the unit model and type of gas supply (natural gas or 
propane) agree with the specifications on the rating plate riveted to the right side of the 
unit in the upper front corner. If the supply and equipment requirements do not agree, do 
not proceed with the installation. Contact your dealer immediately. 
 
LOCATION 
The installation location must be kept free and clear of combustibles.  Do not obstruct the 
flow of combustion and ventilation air. DO NOT install the hotplate adjacent to open 
burners or fryers. 
Sufficient air should be allowed to enter the room to compensate for the amount of air 
removed by any ventilating system and for combustion of the gas burners.  Do not 
obstruct the air flow into and around the hotplate. Position the hotplate in its final 
location.  Check that there are sufficient clearances to service the hotplate and to make 
the required gas supply connection(s).  Provide 24" clearance at the front for cleaning, 
maintenance, service and proper operation.   
Minimum clearances to combustible construction are 6" to the back and 6" to the sides. 
Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides.