GAS CONNECTION 
The data plate on the right side, in the upper front corner of the appliance indicates the 
type of gas your unit is equipped to burn.  DO NOT connect to any other gas type. 
CAUTION:  All gas supply connections and any pipe joint compound must be 
resistant to the action of propane. 
Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting 
the line to the unit. 
Codes require that a gas shut-off valve be installed in the gas line ahead of the 
appliance.  The gas supply line must be at least the equivalent of ¾” iron pipe.   
An adequate gas supply is necessary.  Undersized or low pressure lines will restrict the 
volume of gas required for satisfactory performance.  A minimum supply pressure of 7" 
W.C. for natural gas and 11" W.C. for propane gas is recommended.  With all units 
operating simultaneously, the manifold pressure on all units should not show any 
appreciable drop.   
When testing the gas supply piping system, if test pressures exceed ½ psig (3.45 kPa), 
the appliance and its individual shutoff valve must be disconnected from the gas supply 
piping system.  When test pressures are ½ psig (3.45 kPa) or less, the appliance must be 
isolated from the gas supply piping system by closing its individual manual shut-off valve 
during any pressure testing of the system. 
WARNING:  PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR 
LEAKS.  USE SOAP AND WATER SOLUTION.  DO NOT USE AN OPEN FLAME. 
GAS PRESSURE REGULATOR INSTALLATION 
Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C. 
for propane gas. Minor adjustments may be required based on site specific gas pressure. 
Install the regulator as close to the hotplate on the gas supply line as possible. Make sure 
that the arrow on the underside of the regulator is oriented in the direction of gas flow to 
the hotplate (Fig. 2) and the regulator is positioned with the vent plug and adjustment 
screw upright (Fig. 3). 
 
Fig. 2 
 
Fig. 3 
The minimum supply pressure (upstream of the regulator) should be 7-9” W.C. for natural 
gas and 11-12” W.C. for propane gas. At no time should the hotplate be connected to 
supply pressure greater than ½ psig (3.45 kPa) or 14” W.C.