11. MAINTENANCE & TROUBLESHOOTING 
 
11-2 
 
11.2 Maintenance 
Regular maintenance is vital for maintaining performance. Following the procedures below 
will help keep the equipment in top operating condition. 
Maintenance check points 
Item Check 
Point 
Remedy/Remarks 
Antenna 
Check for physical damage and 
corrosion. 
Replace damaged parts. 
Wire 
antenna 
Check that the antenna is properly 
spanned and separated sufficiently 
from metallic structures. 
If necessary, re-span antenna. 
Insulators 
for antenna 
Check for salt water deposits on 
insulators. Check that connection at 
the lead-in insulator is tight and 
rust-free. 
Replace damage insulators. Remove 
salt water deposits. Clean with fresh 
water, then dry. Remove rust, then 
tighten bolts and lock nuts. Cover 
metallic surface with sealing 
compound. 
Antenna 
coupler 
•  Check condition of antenna terminal, 
ground, coaxial cable and control 
cable.  
•  Check that coupler lid and cable 
glands are firmly secure. 
Check for physical damage, corrosion 
and salt water deposits. 
•  Tighten loosened 
 connections. 
•  Fasten lid firmly and evenly to 
prevent water leakage. 
•  Replace if damaged. 
Control 
unit 
•  Check ground connection, control 
cable, and external equipment. 
Confirm that there are no objects on 
the top of the control unit. 
•  Remove dust from control unit with 
soft cloth. 
 
Note: Do not use chemical cleaners to 
clean the control unit; they can remove 
paint or markings or deform the 
equipment. 
•  Tighten loosened 
  connections; remove foreign 
 material from connectors. 
•  Remove any objects. 
•  Wipe the LCD carefully to 
  prevent scratching, using 
  tissue paper and an LCD 
  cleaner. To remove dirt or salt 
  deposits, use an LCD cleaner, 
  wiping slowly with tissue 
  paper so as to dissolve the 
  dirt or salt. Change paper 
  frequently so the salt or dirt 
  will not scratch the LCD. 
Transceiver 
unit 
•  Check connection at signal cable, 
coaxial cable, control cable, power 
cable, and navigator. 
•  Confirm that there are no objects on 
the top of the cabinet. 
•  Tighten loosened connections; 
remove foreign material from 
connectors. 
•  Remove any objects. 
Power supply 
•  Check that the supply voltage at 
transmission is within the rated range
  (21.6 to 31.2 VDC at the power 
 connector). 
•  If not within the range, check 
  ship’s mains or ship’s battery. 
  Low voltage may cause 
 erratic operation.