11. MAINTENANCE & TROUBLESHOOTING 
 
11-4 
 
11.4 Error 
Messages 
The table below shows error messages, their meanings, and remedies. If oter error occurs, 
contact your dealer. 
Error messages 
Error message 
Meaning 
Remedy 
Busy: RT 
Radiotelephone is in operation. 
Wait until the radiotelephone is 
free. 
Channel Busy 
You attempted to transmit on a 
channel which is currently busy. 
(This occurs with Routine and 
Business priorities only.) 
The message is automatically 
erased when the channel becomes 
clear. 
EPFS error 
No position data from navigator for 
one minute. 
Press the CANCEL key to silence 
the alarm. Check the navigator. If it 
is malfunctioning, manually enter 
position. 
Incoming 
Incoming DSC call 
Message is automatically cleared 
when DSC signal has gone. 
No position data 
The position data is interrupted 
while AUTO operation. 
Check the navigator.   
No response: RT 
Radiotelephone is not powered or is 
disconnected. 
Check radiotelephone connection. 
Oven cold. Tx not 
ready; wait 
Oven too cold; cannot transmit. 
Wait until the oven becomes 
sufficiently warm. 
Printer not ready 
Automatic print is selected; 
however, printer is not powered or is 
disconnected. 
Check printer. 
Trouble: Oven not 
ready 
Oven not ready; cannot transmit. 
Wait until the oven is ready. 
TRX PLL UNLOCK 
TRX PLL unlock. Transmission is 
stopped. 
Contact your dealer. 
TUNE error 
Tuning failed. Transmission power is 
decreased to LOW2. For NBDP, 
transmission is stopped. 
Try to tune again. If unsuccessful, 
confirm if TUNE error occurs on 
other frequencies. See “Antenna 
coupler cannot tune antenna” on 
page 11-3, or contact your dealer. 
Warning: Update 
position 
Position data is older by the amount 
of time preset on the Alarm menu.   
Press the CANCEL key to silence 
alarm. Reenter position on the 
Position menu. 
Watchdog error. 
Please Power OFF 
Internal error (such as CPU trouble) 
detected. Accompanied with alarm, 
same type as for distress. 
Turn the power off and on to erase 
the message. Have a qualified 
technician check the set. 
RX1 PLL UNLOCK 
RX2 PLL UNLOCK 
W/R1, W/R2 PLL unlock. 
Transmission is stopped. 
Contact your dealer. 
Ship’s mains failure  Power input has been switched from 
AC to DC at PR-850A. 
Press the CANCEL key to use the 
low output power. Check the AC 
input supply.