National Instruments SCC-TC01 Manual De Usuario

Descargar
Página de 20
SCC-TC Series Thermocouple Input Modules User Guide
18
ni.com
I/O Connector Pin Assignments
Figure 4 shows the I/O connector pins on the bottom of the module.
Figure 4.  SCC Module Bottom View
Table 1 lists the signal connection corresponding to each pin. ACH(X) and 
ACH(X
+8) are the analog input signal channels of the E Series DAQ 
device. AIGND is the analog input ground signal and is the reference for 
ACH(X) and ACH(X
+8). AGND is the reference for the ±15 V supplies and 
REF5V. AIGND and AGND connect to the SC-2345 at the SCC-PWR 
connector.
Table 1.  SCC Module Pin Signal Connections for SCC-TC0X Modules
Pin Number
Signal
1
ACH(X)
2
3
4
ACH(X
+8)
5
6
AIGND
7
8
9
10
11
AGND
12
REF5V
12
3
19
20
17
18
15
16
13
14
11
9
10
7
8
5
6
3
4
1
2