3.13.  Strobe Delay / Duration Table   
The table shows the strobe index by increment step through the strobe delay time and the strobe duration time. The 
Increment Step is different according to strobe index. Fire-i 501/511/601 and Fire-i 701/702/810 have different range 
for strobe delay and duration in the index table.   
 
Fire-i 501/511/601 
  Strobe Delay/Duration Table 
Strobe Index(Y) 
Increment Step 
Strobe Delay Time : T 
Delay Time 
Duration Time 
Range 
0  
0us
N.A
1  
1us
N.A
2  
2us
2us
3~250 1us 
T=Y us
T=Y us
3us~250us
251~489 250us 
T=(Y-250)*250us+250us
T=(Y-250)*250us+250us 500us~60ms
Strobe Delay/Duration Index 
  Strobe Delay Time 
Strobe Duration Time 
0 0us
N.A 
1 1us
N.A 
2 2us
2us 
10 10us
10us 
100 100us
100us 
250 250us
250us 
253 1ms
1ms 
257 2ms
2ms 
269 5ms
5ms 
289 10ms
10ms 
329 20ms
20ms 
449 50ms
50ms 
489 60ms
60ms 
 
Fire-i 701/702/810 
Strobe Delay Table 
Strobe Index(Y) 
Increment Step 
Strobe Delay Time : T 
Delay Time 
Range 
1us 
 
0us
0us 
1 1us
1us 
2 2us
2us 
3~250 
T=Y us
3us~250us 
251~3900 
T=Y us
251us~3900us