INSTEON 2474dwh Manual De Usuario

Descargar
Página de 15
 
Page 7 of 15  
                
2474DWH- Rev: 1/21/2014 7:30 AM
 
Note that a link is one way. If you wish to have two-way control, simply add a link from the responder to 
the controller.  
Make SwitchLinc an INSTEON Responder 
Follow the steps below to create a link, enabling another INSTEON device to control SwitchLinc. 
 
1)  Press and hold controller button until beep. 
 
 
Controller LED will start blinking 
green
.
 
 
2)  Adjust SwitchLinc to desired brightness for link. 
Load will turn on and LED will turn white. 
3)  Press and hold SwitchLinc Set button until double-beep. 
 
 
Controller will double-beep and LED will stop blinking. 
4)  Test by tapping controller button on and off.  
 
 
SwitchLinc will turn on and off. 
Notes: 
The link just created is one way. Se
 to add another link to 
keep the two products in synch. 
If you wish the load to be off when link is activated (such as for an “all off” scene), turn the load off in 
step 2. 
Make SwitchLinc an INSTEON Controller 
Follow the steps below to create a link, enabling SwitchLinc to control another INSTEON device. 
1) 
Press and hold SwitchLinc Set button until beep. 
LED will start blinking 
green
2) 
Adjust responder to desired brightness/state.
 
3) 
Press and hold responder Set button until double-beep. 
 
 
SwitchLinc LED will stop blinking.
 
 
 
SwitchLinc will double-beep.
 
4) 
Test by tapping SwitchLinc paddle on and off. 
 
 
 
Responder will turn on and off. 
Notes: 
To add multiple responders, repeat steps 1-5. 
The link just created is one way. Se
 to add another link 
to keep the two products in synch. 
 
Synchronizing Devices in Groups 
Devices in a group share all the same settings (e.g., on-level, ramp rate). This keeps all group members 
synchronized. Every device in a group is both a controller of and a responder to all the other devices. The 
most common example of a group is a 3-way lighting circuit (2 switches controlling the same load). 
The following steps will create a virtual 3-way circuit including device A and device B. For simplicity, we 
will assume that the desired group level is “all on.” 
 
1)  Turn both A and B on. 
2)  Press and hold A’s Set button until beep. 
 
 
A status LED will start blinking 
green
3)  Press and hold B’s Set button until double-beep. 
 
 
A will double-beep and its LED will stop blinking. A is now a controller of B. 
                                                      
1
 If the responder is a multi-scene device such as a KeypadLinc, tap the scene button you wish to control until its LED is in the desired scene state (on or off).  You can program 
any state, not just on, for the responder’s link. 
2
 If either the SwitchLinc or responder’s LED continues to blink, the addition failed. Tap the device’s Set button until LED stops blinking and try again. 
3
 If either the SwitchLinc or responder’s LED continues to blink, the addition failed. Tap the device’s Set button until LED stops blinking and try again.