Cisco Systems ATA 188 Manual De Usuario

Descargar
Página de 228
 
5-41
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (H.323)
OL-4008-01
Chapter 5      Parameters and Defaults
Optional Feature Parameters
Call-Progress Tone Parameters
This section contains the following topics:
List of Call-Progress Tone Parameters
The following list contains the names of the call-progress tone parameters:
DialTone
BusyTone
ReorderTone
RingBackTone
CallWaitTone
AlertTone
Tone Parameter Syntax
Each tone is specified by nine integers, as follows:
ntone, freq0, freq1, level0, level1, steady, on-time, off-time, total-tone-time
ntone is the number of frequency components (0, 1 or 2).
freq[0] (Hz) is the transformed frequency of the first frequency component (-32768 to 32767). 
Note
Only positive values can be configured to the Cisco ATA 186. For negative values, use the 16-bit 
2’s-complement value. For example, enter -1 as 65535 or 0xffff. 
freq[1] is the transformed frequency of the second frequency component (-32768 to 32767).
level[0] is the transformed amplitude of the first frequency component (-32768 to 32767).
level[1] is the transformed amplitude of the second frequency component (-32768 to 32767).
steady controls whether the tone is constant or intermittent. A value of 1 indicates a steady tone and 
causes the Cisco ATA to ignore the on-time and off-time parameters. A value of 0 indicates an on/off 
tone pattern and causes the Cisco ATA to use the on-time and off-time parameters.
on-time controls the length of time the tone is heard in milliseconds (ms) expressed as an integer 
from 0 to 0xffff sample at 8000 samples/second.