SERVICE (cont.)
CONTROL BOARD and LEVEL PROBE
FIG. 11 CONTROL BOARD
P1925
Location:
 
The control board is located behind the rear panel, 
mounted on the back side of the hopper motor mount-
ing panel.
Test Procedure:
Liquid Level Control
1.  Disconnect the dispenser from the power source.
2.  Disconnect the twelve pin connector (J1) from the 
control board.
3.  Check the voltage across pins 2 & 3 of the twelve pin 
connector on the wiring harness with a voltmeter. 
Connect  the  dispenser  to  the  power  source  and 
select the “ON” position of the main power switch. 
The indication must be 24 volts ac.
4.  Select the “OFF” position of the main power switch 
and  disconnect  the  dispenser  from  the  power 
source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring harness.
5.  Reconnect the twelve pin connector to the control 
board (J1).
6.  Disconnect the four pin connector (J7) from the 
control board.
7.  Check the voltage across pins 1 & 3 of the four pin 
connector on the wiring harness with a voltmeter. 
Connect  the  dispenser  to  the  power  source  and 
select the “ON” position of the main power switch. 
The indication must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt CE models.
8.  Select the “OFF” position of the main power switch and 
disconnect the dispenser from the power source.
If voltage is present as described, proceed to #9.
If voltage is not present as described refer to the wiring 
diagram and check the dispenser wiring harness.
9.  Reconnect the four pin connector to the control board 
(J7).
10. Disconnect the twelve pin connector (J1) from the 
control board.
11. Measure the resistance between pins 8 & 12 of the 
twelve pin connector on the wiring harness using 
an ohmmeter. The indication must be between 298k 
ohms and 304k ohms.
If  the  resistance  measures  as  described,  proceed  to 
#12.
If the resistance does not measure as described, refer 
to the wiring diagram and check the dispenser wiring 
harness.
12. Carefully connect a piece of insulated jumper wire 
to the level probe contact pin (pink wire) located at 
the lower left rear of the dispenser.
13. Check the voltage across the terminals, first of the 
dispense  solenoid  and  then  of  the  hopper  motor 
with a voltmeter. Connect the dispenser to the power 
source and select the “ON” position of the main power 
switch. The indication must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt CE models.
 
at the dispense solenoid and between 4 and 26 volts 
dc at the hopper motor after a delay of approximately 
10 seconds.
14. Touch the free end of the jumper wire to the dispenser 
housing. The indication must be 0 (zero) after a delay 
of up to 5 seconds.
15. Move the jumper wire away from the housing. The 
indication must again be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt CE models.
 
at the dispense valve solenoid and between 4 and 
26 volts dc at the hopper motor after a delay of up 
to 5 seconds.
16. Disconnect the dispenser from the power source, 
remove the jumper wire, and select the “OFF” posi-
tion on the main power switch.
If voltage is present as described, The liquid level control 
circuitry is operating properly.
If voltage is not present as described, replace the control 
board.
29793 011500