Bunn CDS-3 Manual De Usuario

Descargar
Página de 34
31
SERVICE (cont.)
PRESSURE REGULATOR and NEEDLE VALVE
FIG. 30 PRESSURE REGULATOR
and NEEDLE VALVE
P1935
Location:
The pressure regulator and needle valve are located 
inside the rear panel at the bottom of the dispenser.
Adjustments:
The water pressure regulator is preset at the factory 
to produce 15 psi (103 kPa) of water pressure at the 
regulator outlet with inlet pressures ranging from 20 
psi to 90 psi (138 to 620 kPa). No field adjustments of 
the pressure regulator should ever be necessary.
The needle valve is preset at the factory to dispense 
1 fluid ounce of water per second. The dispenser is 
designed to accommodate various product mix ratios 
by  adjusting  the  product  dispense  rate  (see  Initial 
Setup). Should a readjustment of the water dispense 
rate become necessary, proceed as follows:
1.  Disconnect the dispenser from the power source.
2.  Remove  the  six  #8-32  screws  securing  the  rear 
panel to the dispenser housing.
3.  Turn  the  needle  valve  adjustment  screw  coun-
terclockwise to increase the water flow rate, and 
clockwise to decrease the water flow rate.
Removal and Replacement:
Pressure Regulator
1.  Disconnect the dispenser from the power source 
and the water supply.
2.  Remove  the  six  #8-32  screws  securing  the  rear 
panel to the dispenser housing.
3.  Disconnect the .25” copper tube from the outlet of 
the pressure regulator.
4.  Loosen the nut securing the bulkhead fitting to the 
dispenser.
5.  Remove the bulkhead fitting from the inlet to the 
pressure regulator.
6.  Remove the pressure regulator assembly.
7.  Attach the regulator to the bulkhead fitting making 
sure that the copper bushing is seated properly in 
the regulator and tighten securely.
8.  Tighten the nut securing the bulkhead fitting to the 
dispenser housing.
9.  Attach the .25” copper tube to the regulator as-
sembly and tighten securely.
10. Connect  the  dispenser  to  the  water  source  and 
check for leaks. Tighten any leaking connections 
before installing rear panel.
Removal and Replacement:
Needle Valve
1.  Disconnect the dispenser from the power source 
and the water supply.
2.  Remove  the  six  #8-32  screws  securing  the  rear 
panel to the dispenser housing.
3.  Disconnect the .25” copper tube from the inlet fit-
ting on the needle valve.
4.  Disconnect  the  water  outlet  from  the  solenoid 
valve.
5.  Remove  the  solenoid  valve  and  needle  valve  as 
described in section- Dispense Solenoid Valve.
6.  Remove the needle valve assembly. Remove the 
fitting from the inlet port of the needle valve.
7.  Install the fitting removed from the old needle valve 
onto the new needle valve using pipe thread sealant 
(BOM #M2526.0000).
8.  Attach the needle valve to the fitting on the dispense 
solenoid  valve  using  pipe  thread  sealant  (BOM 
#M2526.0000) and tighten securely.
9.  Install the solenoid valve and needle valve as de-
scribed in section- Dispense Solenoid Valve.
10. Attach water inlet and outlet lines and tighten se-
curely.
11. Connect  the  dispenser  to  the  water  source  and 
check for leaks. Tighten any leaking connections 
before installing rear panel.
29793 011500