SERVICE (cont.)
FIG. 31 DISPENSE SOLENOID VALVE
P1935
DISPENSE SOLENOID VALVE
Location:
The dispense solenoid valve is located on the left 
side of the dispenser base inside of the rear cover.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the white/red and white/brown wires 
from the solenoid valve.
3.  Check the voltage across the white/red and white/
brown wires with a voltmeter. Connect the dispenser 
to the power source. The indication must be: a) 120 
volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt CE models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to wiring 
diagrams and check the dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
white/red and white/brown wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
6.  Check the solenoid valve for coil action. Connect the 
dispenser to the power source. Press the dispense 
switch and listen carefully for a “clicking” sound as 
the magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the 
solenoid valve may require inspection for wear and the 
removal of waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the 
solenoid valve.
Removal and Replacement:
1.  Disconnect the dispenser from the power source 
and the water supply.
2.  Remove  the  six  #8-32  screws  securing  the  rear 
panel to the dispenser.
3.  Remove the white/red and white/brown wires from 
the solenoid valve.
4.  Disconnect the water lines to and from the solenoid 
valve.
5.  Remove the two #8-32 nuts securing the solenoid 
mounting bracket to the dispenser base. Remove 
the solenoid and bracket assembly.
6.  Remove the two #10-32 screws and lockwashers 
securing the solenoid valve to the bracket.
7.  Install a new solenoid valve to the bracket using 
two #10-32 screws and lockwashers.
8.  Install the solenoid and bracket to the base and 
secure with two #8-32 nuts.
9.  Install the water lines to and from the solenoid valve 
using pipe thread sealant (BOM #M2526.0000) and 
tighten securely.
10. Refer to Fig. 32 when reconnecting the wires.
FIG. 32 DISPENSE SOLENOID TERMINALS
P1909
WHI/RED to Control 
Board (J7-2)
WHI/BRN to Control 
Board (J7-4)
29793 011500