Installation - Model IHF165
Ground
The machine must be placed on a flat, solid surface 
(metal base, concrete or solid ground). It is 
recommended that the machine be anchored (M16) on 
the provided places (1) in the base, especially in case 
of a plinth (See Mounting Bolt Hole Locations). Refer 
Figure 17 
The machine must be placed entirely level. For easy 
maintenance it is recommended to keep a minimal 
distance of 23.62 in. (600 mm) between the wall and 
the back of the machine.
If several machines are placed next to each other, there 
should be a minimal distance of 1.18 in. (30 mm) 
between each machine.
Electrical Installation Requirements 
- Model IHF165
Table 4 
CHM2180N
1
Mounting Bolt Holes
1
Machine without electrical heating
240V 3AC
400V 3AC + N
40 A
25 A
Machine with electrical heating
240V 3AC
400V 3AC + N
27 kW
125 A
63 A
36 kW
N/A
80 A