bobcat t190 Manual De Usuario

Descargar
Página de 147
T190 Compact Track Loader
79
Operation & Maintenance Manual
HEATING AND AIR CONDITIONING
Close the rear door before operating the loader.
Cleaning and Maintenance
The heater and air conditioning system require regular
inspection and maintenance. (See SERVICE
SCHEDULE on Page 67.
)
Filters
Figure 140
The Fresh Air Filter is located below the rear window of
the cab (1[Figure 140].
Remove the bolts, the filter housing, and the filter.
Shake the filter or use low air pressure to remove dirt.
Reinstall the filter, housing and bolts.
The  Recirculation Filter is located in front of the rear
window inside the cab (2) [Figure 140].
Remove the clamping knobs, grill and filter.
Clean the filter with water and mild detergent. Reinstall
the filter, grill and clamping knobs.
Evaporator
Figure 141
Raise the cab and remove the evaporator cover (1)
[Figure 141].
Use low pressure water or air to remove debris from the
evaporator fins.
Install the cover.
Lower and secure the cab.
Air Conditioning Lubrication
Run the air conditioner for about 5 minutes every week to
lubricate the internal components.
Troubleshooting
If the fan does not run, or the air conditioning does not
turn on, check the fuse. (See ELECTRICAL SYSTEM on
Page 87
.)
If the air conditioning system circulates warm air, the
refrigerant may need to be recharged.
N-21536
2
1
P19427
1