Section 200 - General Description      
Chapter 2 - System Hardware      
CABINETS
CAB-40 Base Cabinet (VB-44010)
Each CAB-40 Base cabinet supports up to 40 ports using flexible or universal card slots. Dual system 
connection (CAB-40 + CAB 40) is available using connection cable kit. 
Multiple slot types are used in the CAB-40 Base cabinet. These slot types are as follows:  
Optional backup batteries can be installed for system operation in the event of a power failure.
CAB-90 Base/Expansion Cabinet
Two types are cabinets are used in the ICX:
1)
the CAB-96 Base cabinet (VB-44020)
2)
the CAB-96B Expansion cabinet (VB-44021).
Each cabinet provides 96 universal ports. Systems can be configured with one to six cabinets in a 
"building-block" fashion. The bottom cabinet in a column is the Base cabinet. The middle and top 
cabinets in a column must be Expansion cabinets.
The maximum configuration for a fully expanded (6-cabinet) system supports a maximum of 576 
ports, and contains two Base cabinets and four Expansion cabinets (see figure below).
Maximum 6-Cabinet Configuration 
Slot type
# of slots
Unit type to be installed
Power slot
1
Accommodates the cabinet power supply. The power supply comes installed in 
the cabinet.
CPC slot
1
CPC in first Base cabinet (CPC-96);
Flexible slots
5
Accommodates trunk cards, extension cards, other cards (such as MFR), etc. 
Option slots
2