ClearView AVS-PTZ-HD2-C Manual De Propietario

Descargar
Página de 70
 
 
20 
ALARM NO                    
:1
 
ACTION                 
:NONE 
PARAMETER                     :NONE 
CONTACT     
               :N/O         
RELAY OUT    
               :OFF 
RESET DELAY                   :3S 
SAVE   
BACK                                   EXIT 
  PASSWORD: Enable this function here so that you set password is valid. This function is on by 
default after you set password.    
  SETTING: Click the confirm button to go to the password setup interface. Please use the left/right 
button to set the value and then click the confirm button to confirm current option. Move the cursor 
to the SAVE button and then click the confirm button to save current setup. Click the BACK button 
to go to the previous menu.  
  BACK: Go back to the previous menu. 
  EXIT: Log out the system menu. 
If you have forgot your password. After three times of login failure, system may pop up an 8-digit 
internal code. Please contact our technical engineer for help.  
 
3.4.5  Alarm Setting 
 
 
 
 
 
 
 
Figure 3-32 Alarm setting 
Move the cursor to highlight ALARM SETTING button and then click confirm button. 
  ALARM NO: Here is to set alarm input. Alarm input value ranges from 1 to 2. Please use the 
left/right button on the keyboard or in the speed dome terminal menu to set.    
  ACTION: Action on alarm function. It includes NONE/PRESET/AUTO SCAN/TOUR functions. 
Please use the left/right button on the keyboard or in the speed dome terminal menu to set.    
  PARAMETER: it is to set corresponding alarm operation such as scan/preset/tour. Please use the 
left/right button to set.    
  CONTACT:You can set system activation operation once alarm occurred. There are two alarm 
signal mode: normal open (N/O) and normal closed (N/C). Please use the left/right button on the 
keyboard or in the speed dome terminal menu to set.    
  RELAY OUT: Here is to set relay alarm mode and reset time. There are several options: 
off/1→5S. 
 
1→5S:1 means the first relay output.5S means the relay will reset automatically in five 
seconds after alarm occurs. 
  RESET DELAY: Here is for you to set alarm reset time. Please use the left/right button on the 
keyboard or in the speed dome terminal menu to set: 3 seconds/10 seconds/30 seconds/60 
seconds /120seconds. The dome will go back to previous setup after alarm acknowledgement. 
  SAVE:Move the cursor to SAVE and then click confirm button to save current setup. 
  BACK: Go back to previous menu.  
  EXIT: Log out system menu. 
 
3.5  Dome Abnormal Phenomenon Operation 
3.5.1 Restore to Factory Default Setup 
From  main  menu->  SYSTEM  INFORMATION,  move  cursor  to  FACTORY  DEFAULT  and  click  confirm 
button. Dome will reboot and all the setups restore to factory default setup. 
3.5.2 PTZ Movement is not smooth