5. Installing, Starting and Stopping the SecurNozzle 
 
The SecurNozzle and all of its components, including the battery, must be assembled, 
disassembled, installed or uninstalled only by Securant Certified Technician.  Installing or 
uninstalling of the SecurNozzle or any SecurNozzle component, including the battery, by other 
than a Technician can be DANGEROUS and immediately voids all product warranties. 
 
5.1. 
Installing the Battery on SecurNozzle 
 
The SecurNozzle battery has to be assembled in the SecurNozzle and replaced only by a 
Securant Certified Technician specially instructed in this function.  The battery should be 
installed or uninstalled only in a Technical Service Centers specially equipped for this 
installation and located a minimum of _______ feet from any fueling facility.  . 
 
Battery installation must be performed in accordance with the SecurNozzle manufacturing 
instructions utilizing proper parts and materials as defined by the SecurNozzle Bil of Materials 
including certified sealing material, glue and screws. 
 
Only batteries defined in the SecurNozzle Bill of Materials should be installed in the 
SecurNozzle.  Installation of any battery other than a battery specified in the SecurNozzle Bill of 
Materials can be DANGEROUS and may cause injury.   
 
Operating Temperature 
From -40°C to 80°C 
 
Storage Temperature 
From -40°C to 100°C 
 
Relative Humidity 
< 97% non-condensing,  
IEC 68-2-30  
Environmental Safety 
 
 
Intrinsic Area 
          regulation standards 
EN 60079,UL 913, 
CSA C22.2 
 No. 157 3
rd
 Ed Intrinsic Safety for 
Hazardous Location
 
 
Electromagnetic 
compatibility regulations 
ETSI EN 300 330-V1.3.1 (2001- 06) and  
ETSI EN 300 330-V1.1.1 (2001- 06). 
Mechanical Endurance 
 
 
Mechanical Vibration 
                endurance standard 
IEC 68-2-6, Test Fc; 20 g, 20 - 500 Hz,  3 axes, 10 
cycles per axis  
 
Mechanical Shock 
            endurance standard 
IEC  68-2-27,  Test  Ea;  200  g,  half  sine,  3  ms,  3 
axes, 6 shocks per axis