Securant Inc SNSIV10 Manual De Usuario
Securant Fueling Systems (Israel) Ltd.
Tel: +972 (0)3 6894550; Fax: +972 (0)3 6894540.
55 Igal Alon St., Tel-Aviv 67891, ISRAEL
Page 9 of 15
5. Installing, Starting and Stopping the SecurNozzle
The SecurNozzle and all of its components, including the battery, must be assembled,
disassembled, installed or uninstalled only by Securant Certified Technician. Installing or
uninstalling of the SecurNozzle or any SecurNozzle component, including the battery, by other
than a Technician can be DANGEROUS and immediately voids all product warranties.
5.1.
Installing the Battery on SecurNozzle
The SecurNozzle battery has to be assembled in the SecurNozzle and replaced only by a
Securant Certified Technician specially instructed in this function. The battery should be
installed or uninstalled only in a Technical Service Centers specially equipped for this
installation and located a minimum of _______ feet from any fueling facility. .
Battery installation must be performed in accordance with the SecurNozzle manufacturing
instructions utilizing proper parts and materials as defined by the SecurNozzle Bil of Materials
including certified sealing material, glue and screws.
Only batteries defined in the SecurNozzle Bill of Materials should be installed in the
SecurNozzle. Installation of any battery other than a battery specified in the SecurNozzle Bill of
Materials can be DANGEROUS and may cause injury.
Operating Temperature
From -40°C to 80°C
Storage Temperature
From -40°C to 100°C
Relative Humidity
< 97% non-condensing,
IEC 68-2-30
IEC 68-2-30
Environmental Safety
Intrinsic Area
regulation standards
EN 60079,UL 913,
CSA C22.2
CSA C22.2
No. 157 3
rd
Ed Intrinsic Safety for
Hazardous Location
Electromagnetic
compatibility regulations
compatibility regulations
ETSI EN 300 330-V1.3.1 (2001- 06) and
ETSI EN 300 330-V1.1.1 (2001- 06).
ETSI EN 300 330-V1.1.1 (2001- 06).
Mechanical Endurance
Mechanical Vibration
endurance standard
IEC 68-2-6, Test Fc; 20 g, 20 - 500 Hz, 3 axes, 10
cycles per axis
cycles per axis
Mechanical Shock
endurance standard
IEC 68-2-27, Test Ea; 200 g, half sine, 3 ms, 3
axes, 6 shocks per axis
axes, 6 shocks per axis