G FORCE PLUS RF Instruction Manual 
 
 
Apr/08
 76 
Doc #RF1 Rev.9 
REFERENCE 
 
RECOMMENDED SETTINGS 
 
Battery Settings 
 
The recommended situation-specific Battery Fault settings are:  
 
Setting General
High Fault Threshold (SGP) 
1650
Low Fault Threshold (SGP) 
780
 
The recommended situation-specific Battery Charge settings are: 
 
Setting General
Freezer 
Only
OK To Charge Threshold (SGP) 
1200
1200
OK To Charge Timer (minutes) 
45
45
Must Charge Threshold (SGP) 
1150
1160
Must Charge Timer (minutes) 
40
40
 
 
 
 
 
 
 
 
 
Impact Types 
 
A Hard Impact occurs when a Vehicle hits an immovable object such as a post or a Vehicle of the same or 
larger size.  The Vehicle generally stops on impact and its energy is dissipated instantly.  The energy from 
this type of impact is high in amplitude and short in duration (10 ms).   
 
A Soft Impact occurs when a Vehicle hits an object like product or racking.  The Vehicle generally comes 
to a stop some distance after the impact, as it takes some time for its energy to dissipate.  The energy from 
this type of impact is low in amplitude and long in duration (300 ms).  This type of impact tends to be 
most damaging and most often causes an Impact alarm. 
 
 
NOTE! 
For help adjusting Battery settings  
to reflect your company’s charging policy,  
contact Technical Assistance at  
BMI Technologies Inc. at 1-800-563-8867.