REFERENCE
RECOMMENDED SETTINGS
Battery Settings
The recommended situation-specific Battery Fault settings are:
Setting General
High Fault Threshold (SGP)
High Fault Threshold (SGP)
1650
Low Fault Threshold (SGP)
780
The recommended situation-specific Battery Charge settings are:
Setting General
Freezer
Only
OK To Charge Threshold (SGP)
1200
1200
OK To Charge Timer (minutes)
45
45
Must Charge Threshold (SGP)
1150
1160
Must Charge Timer (minutes)
40
40
Impact Types
A Hard Impact occurs when a Vehicle hits an immovable object such as a post or a Vehicle of the same or
larger size. The Vehicle generally stops on impact and its energy is dissipated instantly. The energy from
this type of impact is high in amplitude and short in duration (10 ms).
A Soft Impact occurs when a Vehicle hits an object like product or racking. The Vehicle generally comes
to a stop some distance after the impact, as it takes some time for its energy to dissipate. The energy from
this type of impact is low in amplitude and long in duration (300 ms). This type of impact tends to be
most damaging and most often causes an Impact alarm.
NOTE!
For help adjusting Battery settings
to reflect your company’s charging policy,
contact Technical Assistance at
BMI Technologies Inc. at 1-800-563-8867.