Cavotec Micro-control as MC-3-6TERM Manual De Usuario

Descargar
Página de 9
 
 
 
Micro-control as 
Operation and Maintenance Manual for MC-3-series 
Page 9 of 9 
MAN-05-006  
Rev. 
Table 2: Possible indications in the Base Unit display 
If the system has a 4 digit LED module the indicated codes are displayed there. If the system has a 
LCD module the error codes are displayed in a field in the display. 
 
Display  Description Action 
”XXX” 
System ID code. 
Is normally displayed a short moment when the 
terminal is “turned on”. Is displayed in systems 
with only one terminal. 
None 
”XXX.Y”  System ID code and terminal number. 
Is normally displayed a short moment when the 
terminal is “turned on”. Is displayed only in 
systems with more than one terminal. 
None 
”X.YY” 
The battery voltage measured in volts.  
(The number displayed has two decimals, the 
values will be between 6.40 and 9.00.) 
Is normally displayed a short moment when the 
terminal is “turned on”. 
None 
”A-XX” 
Analog channel that can be programmed. (The 
number displayed is an integer between 1 and 
13.) 
Is displayed only when the terminal is in 
programming mode. 
None 
” A-00” 
No analog channel is activated. 
Is only displayed when the terminal is in 
programming mode. 
Activate the analog channel that you wish 
to program! 
E001 
Processor fault.  
Indicates a processor module fault and/or a 
processor fault. 
Ensure that the processor module 
BOOT-jumper is not turned on!  
Replace the processor module and/or the 
processor! 
E002 
Activity at start-up.  
A joystick is out of center position, or a switch is 
in ON-position. 
Set all switches/joysticks to OFF-position 
and/or neutral position! 
 
E003 
Radio fault. 
Change the Radio module. 
E004 
Shutdown because of low battery voltage. 
Replace the battery! 
E005 Keyboard 
fault. 
The terminal is not able to ”read” switches, 
joysticks etc.  
There is a fault at the MC-ITX input 
module. 
E006 
Shutdown because of inactivity. 
The terminal will soon ”turn itself off” since no 
switches, joysticks etc. has been activated. 
Activate a function. 
E007 Priority 
stop. 
The stop button or the chock detector has been 
activated. 
Turn the terminal OFF and ON again to 
start normal operation!