INSTALLATION & OPERATION 
Table 5.  DIP Switch 2 Settings. 
SW 2 
Function 
Description 
Default 
Select 
PTT Delay 
Enables 50 ms delay of PTT for use with simplex 
function. 
OFF 
Simplex Enable 
Enables simplex function* 
ON 
Tx Timer 
Sets programmable Tx time out timer on 
ON 
Repeater Enable 
Enables repeater function* 
ON 
Tx VCO on continuously  Switches Tx VCO on continuously. 
OFF 
Scan on 
Selects the Rx to enable the scanning of 
programmed scan channels. 
OFF 
Note. 
For the Repeater Enable functions, if the switch is ON and the channel is programmed 
as a repeater channel (using MxTools) the SB2025 will act as a repeater.  If the switch 
is OFF the SB2025 will remain in full duplex mode even if the channel is programmed 
as a repeater.  The Simplex Enable operates in a similar way. 
3.2.2.3 
Select Operating Channel 
The  SB2025  has  a  channel  capacity  of  255.    The  RF  and  Continuous  Tone  Coded  Sub-audible 
Squelch  (CTCSS)  frequencies  for  each  channel  are  programmed  using  the  MxTools  Channel 
Information screen.  There are two ways of selecting the operating channel. 
1. 
DIP  Switch  8-way.    DIP  switch  SW1  provides  a  binary  channel  selection  facility.   When  a 
switch is ON it is read as a logical 1.  When all switches are off the software channel select 
mode is enabled. 
2. 
Software Channel Select.  If DIP switch SW1 is set to 0 (zero) then it is possible to send a 
software command to the radio to select the channel. 
The following rules apply. 
Note. 
The  assumptions  of  logic  levels  are  base  on  the  factory  default  setup.    The  Active 
state is Low. 
DIP1  switches  have  priority  over  channel  change.    If  any  of  DIP1  switches  are  set  to  ON  (logic 
low), the rear inputs and the software Channel command will be ignored. 
If DIP1 switches are set to OFF (logic high), the software commands will select the channel. 
3.2.2.4 
Configure Alarms/M Lead 
The  SB2025 has three  open collector outputs.  Two of these are assigned as alarm outputs and 
one  (Output  1)  may  be  configured  as  either  an  alarm  output  or  an  M  Lead  output.    However, 
Output  1  should  be  configured  as  an  M  Lead,  this  line  is  active  when  mute  is  open  and 
CTCSS/DCS  (Digital  Coded  Squelch)  is  decoded.    These  outputs  are  assigned  on  the 
Configuration screen of MxTools. 
3.2.2.5 
Configure Digital I/O 
The SB2025 has 16 digital Input/Output (I/Os).  These are configured using the ET.