INSTALLATION & OPERATION
Jumper
Function/Description
Default
Selection
Default
Position
JMP10
Controls the direction of the RS-232 Tx and Rx data.
Swap
2-3
JMP11
Controls the direction of the RS-232 Tx and Rx data.
Swap
2-3
JMP12
No effect in SB2025.
1-2
JMP13
No effect in SB2025.
1-2
JMP14
No effect in SB2025.
1-2
JMP15
No effect in SB2025.
2-3
JMP16
No effect in SB2025.
2-3
JMP17
Selects the Mute/Squelch output polarity to either normally
high or low.
high or low.
Active low
1-2
JMP18
No effect in SB2025.
Active low
1-2
JMP19
No effect in SB2025.
Pull up
2-3
JMP22
No effect in SB2025.
Low gain
Not fitted
JMP23
No effect in SB2025.
Disabled
Not fitted
JMP24
No effect in SB2025.
1-2
Mute defeat enable. Mute defeat cannot be used if RX
TALK line is required. To use mute defeat remove JMP12
and fit JMP 25. The control signal polarity can be inverted
by changing the position of JMP25.
Active low control:
TALK line is required. To use mute defeat remove JMP12
and fit JMP 25. The control signal polarity can be inverted
by changing the position of JMP25.
Active low control:
JMP25
2-3
JMP25
Active high control:
JMP25
1-2
Disabled
Not fitted
JMP26
CTCSS O/P / Tx VF Loopback control
Tx VF
Loopback
2-3
JMP27
CTCSS I/P / WB DCFM I/P
WB DCFM
I/P
2-3
T99
Option Link
IN
When the SB2025 option card is not fitted, there is no connection made to SKK (Aux 2 connector)
on the Micro Controller. Links should be placed across SKK1-2 (Discriminator audio), SKK11-12
(Tx supply) and SKK13-14 (Rx supply). These links are normally fitted in production.
on the Micro Controller. Links should be placed across SKK1-2 (Discriminator audio), SKK11-12
(Tx supply) and SKK13-14 (Rx supply). These links are normally fitted in production.
3.2.2.2
Select Operating Mode
The SB2025 can operate in a number of different modes. The primary alternatives are full duplex,
which is the default mode, repeater and simplex. Using MxTools, the operating mode is
programmed for each channel. When a channel is selected in operation, the SB2025 adopts the
mode programmed for that channel.
which is the default mode, repeater and simplex. Using MxTools, the operating mode is
programmed for each channel. When a channel is selected in operation, the SB2025 adopts the
mode programmed for that channel.
The operating mode programmed in the software can be modified by the settings of DIP Switch 2.
The functions of this switch are detailed overleaf in Table 5.
The functions of this switch are detailed overleaf in Table 5.