Simoco EMEA Ltd SB2K5354O2O2V Manual De Usuario

Descargar
Página de 202
 
SGD-SB2025NT-TUM, Part 1 
Jan 12 
Page 56 
ALIGNMENT & TESTING 
Procedure 
3. 
Remove PA top cover. 
4. 
Measure  the  resistance  of  the  thermistor  between  CN4-6  and  CN4-4,  this  should  be 
approximately 2 kΩ. 
5. 
Connect DC power lead and 10-way connector from SB2025NT. 
6. 
Connect the PA RF output to the RF Power Meter and the PA RF input (CN1) to RF Signal 
Generator. 
7. 
Set the Signal Generator to centre frequency of PA under test and reduce the RF drive level 
(from signal generator) to zero. 
8. 
Switch on DC power and check that supply is present on L6. 
9. 
Assert  PTT  (check  that  no  output  RF  power  is  emitted  from  the  PA)  and  check  that  the 
13.8 V supply is switched through to source of TR1 and TR2. 
10.
 
With  PTT  ON,  measure  the  PA  bias  current  at  the  gates  of  the  Field  Effect  Transistors 
(FETs).  The Bias current is band dependent.  This is done by monitoring the current drain of 
the whole PA with CN1 disconnected. 
11.
 
Link the gate of TR2 to GND. 
12.
 
Measure  current  consumption  (VHF  Low  Band  400  mA,  VHF  High  Band  200  mA,  UHF 
400 mA.)  This can be adjusted by RV2.  Measure gate volts ≈ 3.4 V. 
13.
 
Remove link from TR2. 
14.  Measure the current consumption and adjust RV1 so that current is 2 Amp total for the VHF 
High Band & UHF Band, and 1 Amp for VHF Low Band.  Measure gate volts ≈ 3.9 V. 
15.  With  PA  transmitting  at  50 W  into  50  Ω  load, measure  DC  volts  FWD  power  sense  CN4-8 
and  REFL  power  sense  CN4-5.    These  voltages  should  be  approx.  2.8  V  and  <250  mV 
respectively. 
16.  Reduce the RF drive until the PA output is 10 W.  Disconnect the PA RF output cable. 
17.  Measure  the  DC  voltage  on  CN4-8  and  CN4-5  again.    These  should  now  both  read  lower 
approximately 1 V. 
18.  Remove PTT. 
6.2.4 
VCO Board 
Test Equipment Required 
• 
Tested SB2025NT with Exciter VCO removed. 
• 
PC with MxTools software installed. 
• 
RF Communications Test Set. 
• 
Multimeter. 
• 
Oscilloscope. 
• 
+13.8 VDC Power Supply.