Simoco EMEA Ltd SB2K5354O2O2V Manual De Usuario

Descargar
Página de 202
 
SGD-SB2025NT-TUM, Part 1 
Jan 12 
Page 57 
ALIGNMENT & TESTING 
Preliminaries 
1. 
On  the  MxTools  Channel  screen,  program  the  upper,  middle  and  lower  frequencies  of  the 
frequency band (refer to Appendix A for band split details) into three channels. 
Note. 
The ‘Continuous Update Enabled’ option on the MxTools Channel Edit screen should 
be selected for these tests. 
2. 
Remove  the  top  cover from  Exciter module  and  fit  the  VCO  under  test.   As  the  Tx  and Rx 
VCOs are identical, the Rx VCO may also be tested in an Exciter.  As the Rx VCO operates 
at the frequencies F
RX
 – 90 MHz. 
3. 
Connect the Exciter to a working Micro Controller via 16-way ribbon cable. 
4. 
Disconnect Exciter RF drive output CN1 from PA. 
Procedure 
5. 
Select mid channel. 
6. 
Connect SKU from the Exciter to VCO. 
7. 
Switch on the DC power. 
8. 
Assert PTT and measure the RF output power on VCO SKT-6.  This should be in the range 
0 dBm to +3 dBm. 
9. 
Measure the RF output level on SKU-1.  This should be in the range 0 dBm to +3 dBm. 
Note. 
If SKU-1 is disconnected from the Exciter the loop will lose lock. 
10.  Reconnect SKT and SKU to Exciter. 
11.  Select lower channel. 
12.  Assert PTT and check that loop is locked. 
13.  Adjust trim cap CT1 on VCO for 3 VDC (2 VDC for N2 band) on SKT-1. 
14.  Select  upper  channel  and  check  that  the  loop  is  locked  and  that  the  voltage  on  SKT-1  is 
<18 VDC. 
The following test is not required for the Rx VCO. 
15.  Connect  the  Exciter  output  to  the  CTS.    Inject  1  kHz  tone  at  nominal  line  input  level  and 
check that Exciter RF output is modulated and that the depth of modulation can be controlled 
through the MxTools Channel screen. 
6.2.5 
Microcontroller Module 
Comprehensive testing of the Micro Controller can only be carried out at the Factory.