FAULT FINDING 
3. 
The Micro Controller PCB requires specialised test software to check all the hardware input 
and  output  ports.    Please  contact  Simoco  Customer  Services  and  arrange  for  the  Micro 
Controller PCB to be returned to Simoco’s Service Centre. 
7.3  R
ECEIVER 
M
ODULE
 
7.3.1 
VCO Locking. 
1. 
In MxTools, check that all hardware settings are correct. 
2. 
On  the  Rx  Module,  check  the  value  of  X3  (13  MHz  or  14.4  MHz)  is  the  same  as  the  Rx 
Reference Frequency in the ‘Hardware Settings’ on the MxTools configuration menu. 
3. 
On the Microcontroller PCB, connect a Digital Voltmeter (DVM) to the Rx VCO TP and check 
the Rx locking voltage is between 2 V – 18 V. 
4. 
Check that +12 V (SKD-2) and 28 V (SKD-13) supply lines are present. 
5. 
If the Rx locking voltage is out of specification, on the Rx VCO, slowly adjust CT1 a full 360° 
and check for a change in the locking voltage. 
6. 
If  there  is  a  change  in  the  Rx  VCO  locking  voltage,  realign  the  VCO  voltage  to  9  V  at  the 
centre frequency of the Rx band. 
7. 
If there is no change in the Rx VCO locking voltage, check that the VCO supply voltage at 
SKU-3 is approximately 7 V and, with an Oscilloscope, check the TCXO is oscillating on pin 
8 of IC10. 
8. 
If  all  the  above  tests  fail,  the  VCO  or  IC10  may  be  faulty.    Contact  Simoco  Customer 
Services and arrange for the Rx Module to be returned to Simoco’s Service Centre. 
7.3.2 
Rx Front End 
1. 
Solder  a  2-way  Berg  header  onto  a  flying  coax  lead.    Remove  solder  link  I  near  the mixer 
(M1)  and  fit  solder  link  J.    Inject  a  RF  signal  into  CN5.    Check  that  the  sensitivity  is  better 
than –110 dBm. 
2. 
If the sensitivity is OK past this point, check that the supply voltage to IC12 is approx. 8 V.  If 
the supply is OK, replace IC12.  If this does not repair the Rx, the alignment may be incorrect 
or other components on the front end may be faulty.  Go to Section 6.2.2
7.3.3 
IF Section 
1. 
If the Rx has low sensitivity past this point, increase the RF level to –60 dBm and ensure the 
Rx DISC voltage is set to 2.50 V.  If necessary, adjust L14 for the required voltage. 
2. 
Connect  a  coax  lead  with  a  pickup  loop  around  the  end  from  the  antenna  input  on  the 
HP8920A to the case of X1.  Set the HP8920 to Tx test, change the Tune Mode to Manual 
and change the centre frequency of the CTS to 44.545 MHz for A to B Band and 89.545 MHz 
for C Band and above. 
3. 
If CT1 cannot be adjusted to match the above frequencies, X1 may be faulty. 
4. 
Set  the  centre  frequency  of  the  HP8920A  to  the  Rx  freq.  +  45  MHz  for  A  to  B  band  or  Rx 
freq. + 90 MHz for C to M Band or Rx freq. – 90 MHz for N band and above. 
5. 
Adjust the TCXO to within ± 20 Hz. 
6. 
If the Rx centre frequency cannot be adjusted, the TCXO may be faulty.