Simoco EMEA Ltd SB2K5354O2O2V Manual De Usuario

Descargar
Página de 202
 
SGD-SB2025NT-TUM, Part 1 
Jan 12 
Page 61 
FAULT FINDING 
7. 
Adjust T1 and T2 for minimum distortion <1%. 
8. 
If the distortion is high, FL3A, FL3B or FL4 may be faulty. 
9. 
If the sensitivity is still poor, contact Simoco Customer Services and arrange for the Module 
to be returned to Simoco’s Service Centre. 
7.4  E
XCITER 
M
ODULE
 
7.4.1 
VCO Locking 
1. 
On  the  Exciter  module,  check  the  reference  frequency  of  X3  (13  MHz  or  14.4  MHz)  is  the 
same  as  the  Tx  Reference  Frequency  in  the  ‘Hardware  Settings’  on  the  MxTools 
configuration menu. 
2. 
On  the  Micro  Controller PCB,  connect  a DVM  to  the  ‘TX VCO’  test  point  and  check the  Tx 
locking voltage is between 2 V – 18 V. 
3. 
Check that +12 V (SKD-2) and 28 V (SKD-13) supply lines are present. 
4. 
If the Tx locking voltage is out of specification, on the Tx VCO, slowly adjust CT1 a full 360° 
and check for a change in the locking voltage. 
5. 
If there is a change in the Tx VCO locking voltage, realign the VCO voltage to 9 V at centre 
frequency of the VCO frequency band. 
6. 
If there is no change in the Tx VCO locking voltage, check the VCO supply voltage at SKU-3 
is approx. 7 V and, with an Oscilloscope, check the TCXO is oscillating on pin 8 of IC 10. 
7. 
If  all  the  above  tests  pass,  the  VCO  or  IC10  may  be  faulty.    Contact  Simoco  Customer 
Services and arrange for the Exciter Module to be returned to Simoco’s Service Centre. 
7.4.2 
RF Power 
1. 
Using MxTools increase the ‘Transmit Power’ control to maximum and check that the output 
power is greater than +24 dBm. 
2. 
If the Exciter power is low, check for the +8 V supply voltage at the outputs of IC2 and TR4. 
3. 
Use a RF probe to check for gain through IC2 and TR4. 
4. 
Lift R2 and solder a flying lead to the junction of R1 and R2.  Check the output power of the 
VCO is between 0 and +3 dBm. 
5. 
If  all  the  above  tests  pass,  contact  Simoco  Customer  Services  and  arrange  for  the  Exciter 
Module to be returned to Simoco’s Service Centre. 
7.5  P
OWER 
A
MPLIFIER
 
1. 
Firstly,  carry  out  a  visual  inspection  of  all  the  components  on  the  PA  looking  for  any 
damaged components. 
2. 
Connect the input of the PA to signal generator with the RF output switched off. 
3. 
With PTT off, measure the +13.8 V supply at the source of the driver and output FET.  If out 
of specification, check voltage at CN2-2, if no volts check the supply cable.