SDB670 – SERVICE MANUAL 
TNM-M-E-0032 
May 13 
Page 28 
DESCRIPTION 
4.3.8 
Facilities Connector 
The  25-way  D  Type  facilities  connector  can  be programmed for  any  combination of  digital  inputs 
and outputs. 
The connector pin-outs for the 25-way D Type Facilities Connector are shown below in Table 14
Table 14.  Facilities Connector Pin-outs 
Pin 
Function 
Pin 
Function 
Digital Input 
14  Digital Output 
Digital Input 
15  Digital Output 
Digital Input 
16  Digital Output 
Digital Input 
17  Digital Output 
Digital Input 
18  Digital Output 
Digital Input 
19  Digital Output 
Digital Input 
20  Digital Output 
Digital Input 
21  Digital Output 
GPS Rx + 
22  GPS Rx - 
10 
GPS Tx + 
23  GPS Tx - 
11 
1PPS Rx + 
24  1PPS Rx - 
12 
Digital to Analogue Convertor (DAC) 
Output 
25 
0 V 
13 
Supply Voltage 
 
 
The  maximum  current  provided  by  the  supply  voltage  pin  is  1  A,  which  is  protected  by  a  self 
resetting fuse. 
Digital  Outputs  are  open  collector  able  to  sink  300  mA  each;  the  total  for  all  outputs  must  not 
exceed 600 mA.  See Figure 8 overleaf. 
Digital inputs are active low.  Digital high voltages should not exceed 20 V.  See Figure 8
GPS Rx and 1PPS Rx are Differential RS422. 
The  “Analogue  Out”  signal  is  between  0  V  and  5  V  and  software  controlled  to  indicate  various 
functions e.g. RSSI.