SDB670 – SERVICE MANUAL 
TNM-M-E-0032 
May 13 
Page 26 
DESCRIPTION 
 
CAUTION 
The Antenna System must to be protected against lightning by means of an 
earthing system and surge protection device. 
Do not connect Antenna Lightning conductors to the base station or Mains 
Earth. 
 
4.3.2 
Power Input Connection 
Depending on the variant of DMR Base (DC or AC), the power connection can be either a 2 Pin, 
DC connector or a standard IEC AC mains socket. 
For DC power, a 2-pin IP67 DC plug connector is used.  Only two pins are wired to suit the voltage 
range, see Table 9 below. 
Table 9.  DC Power Connector Pin-outs. 
Pin 
Description 
+13.8 V 
Ground 
For  AC  power,  a  standard  IEC  Mains  connector  is  used  (see  Figure  5  below).    An  appropriate 
version of power cord, relevant to the area of use, is supplied with the SDB670 DMR base station 
(see Section 7). 
Figure 7.  AC and DC power connectors. 
4.3.3 
Earth Point 
On  both  the  AC  and  DC  versions,  the  earth  stud  on  the  rear  panel  is  provided  for  protective 
earthing  on  the  equipment.    This  should  be  connected  using  heavy  duty  earthing  wire,  with  a 
capacity greater than mains feed to equipment and with as few bends as possible, typically 6 mm 
Green/Yellow with 5 mm eyelet tag. 
4.3.4 
P4 USB Type B Connector 
The Universal Serial Bus (USB) Type B connector is used as the peripheral connection to a PC.  
The connector pin-outs are detailed below in Table 10
Table 10.  USB Type B Connector Pin-outs. 
Pin 
Function 
Vcc (+5 V) 
Data - 
Data + 
Ground 
Standard IEC AC Mains Connector
2-pin IP67 DC Connector