12 
 
 
8.3. Printed Contrast Signal (PCS) 
 
0.3 or higher 
 
<Conditions> 
MRD   
: 32% and higher (70% or higher reflectivity of space and quiet zone) 
Distance 
: 125 mm from the front edge of the scanner 
Bar code  
: UPC (resolution 0.33 mm, PCS 0.3) specified in Section 8.1.  
 
MRD = Minimum reflectance of white space - Maximum reflectance of black bar 
 
PCS =   
Reflectance of white spece - Reflectance of black bar
 Reflectance of white space
  
 
* Be sure to keep the optical window clean without dirt or scratches, or it may have a bad effect on the reading 
characteristics. 
 
8.4. Minimum Resolution 
 
1D bar code  
: 0.127 mm (Code 39 specified in Section 8.1.) 
GS1 Databar 
: 0.169 mm (GS1 Databar Limited specified in Section 8.1.) 
Stacked code 
: 0.169 mm (PDF417, GS1 Databar Limited Composite specified in Section 
8.1.) 
2D code 
: 0.212 mm (QR Code, Data Matrix specified in Section 8.1.) 
 
<Conditions> 
Bar code  
: Above codes specified in Section 8.1. 
Distance 
: 95 mm from the front edge of the scanner 
Angle : 
α = 0°, β = + 15°, γ = 0° 
Curvature 
: R = ∞ 
 
8.5. Wide Bar Code 
Code 39 with width of 100 mm and resolution of 0.2 mm can be read 
 
<Conditions> 
Bar code  
: Code 39 (resolution 0.20 mm, PCS 0.9) specified in Section 8.1.  
Distance 
: 155 mm from the front edge of the scanner 
Angle : 
α = 0°, β = +15°, γ = 0° 
Curvature 
: R = ∞ 
 
 
Figure 4: Wide Bar Code