OPTOELECTRONICS Co. Ltd. OPN3200N Manual De Usuario

Descargar
Página de 31
OPN-3200n 
Specifications Manual 
 
 
 
 
13 
 
 
8.6. Pitch, Skew and Tilt 
 
Pitch : 
α = ±50° 
Skew : 
β = ±50° 
Tilt : 
γ = ±180° 
 
<Conditions> 
Bar code  
: UPC (resolution 0.33 mm) specified in Chapter 8.1  
Distance 
: 125 mm from the front edge of the scanner 
Curvature 
: R = ∞ 
Angle : 
Pitch  β = +15°, γ = 0° 
 
Skew, Dead zone 
α = 0°, γ = 0° 
 Tilt 
α = 0°, β = +15° 
 
α
β
γ
+
+
+
-
-
-
 
 
Figure 5: Pitch, Skew and Tilt 
 
8.7. Curvature 
 
0.33 mm 12-digit UPC 
: R ≥ 20 mm 
0.15 mm 10-digit Codabar (NW-7) 
: R ≥ 16 mm 
 
<Conditions>  
Bar code 
: UPC (0.33 mm) and Codabar (0.15 mm) specified in Section 8.1. 
Distance 
: 105 mm from the front edge of the scanner 
Angle : 
α = 0°, β = +15°, γ = 0° 
 
R
Bar code
 
Figure 6: Curvature  
 
* The reading characteristics may deteriorate due to the specular reflection of LED illumination when the 